| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Main Switch;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-3;
Rated curret (In): 63A, 80A,100A,125A;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated impulse withstand voltage (Uimp): 6kA;
Electrical life: 4000;
Mechanical life: 20000;
Protection degree: IP20;
Rated making and breaking capacity: 3le, 1.05ue,cosΦ=0.65;
Using the categories: AC-22A;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vs1-12 /Zn63;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 12kv;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Installation: Insert;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Product Name: HD Series 2p Hydromagnetic Magnetic Breaker;
Rating Current: 1A-100A;
Rating Voltage: AC250V, AC415V, DC80V, 50/60Hz;
Pole: 2 Pole/ 2p;
Material: High Flame Retardant Plastic;
Series: HD Series Hydraulic Magnetic Ccircuit Breaker;
Reset Type: Manual Resettable;
Connection Method: Screw-Type/ Pluggable; Bolt/ Plug;
Application: Communications, Laser Equipment, Railway Locomotiv;
Certified: RoHS;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Pole: Single;
Rated Voltage: AC230/400V;
Tripping Curve: B, C, D;
Rated Breaking Capacity: 6000A;
Magnetic Releases Operate: B Curve: Between 3 and 5 in;
C Curve: Between 5 and 10 in;
D Curve: Between 10 and 14 in;
Mechanical Life: 20000times;
Protection Degree: IP20;
Rated Current: 2A 6A 10A 16A 32A 63A;
Rated Frequency: 50/60Hz;
Time Delay: 1.13>1h Non-Trip;
Time Delay 1.45in: 1.45in<1h Trip;
Time Delay 2.55in: 1s<60s Trip;
Stardard: IEC898, CE, CB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage Ue: 230V;
Rated Breaking Capacity: 6000A;
Protection Class: IP20;
|