| Specification |
After-sales Service: 1 Year;
Warranty: on-Site Installation Guidance;
Voltage: DC 24V (19-30V Voltage Range);
Working Mod: Continuous Monitoring of Drainage, Intermittent Au;
Measurement: :90° Scattering;
Range: 0-20 Ntu (31),0-1 Ntu (30);
Zero Drift: ≤±0.015 Ntu;
Value Error: ≤±2% or ±0.015 Ntu L;
Calibration: Formalhydrazine Standard Liquid;
Water Pressure: :0.1 Kg/Cm3-8kg/Cm3, Flow Not Exceeding 300 Ml /Mi;
Digital Output: RS485modbus Protocol;
Analog Output: Ma 4-20;
Storage Temperature: -20℃-60℃;
Working Temperature: 0-50 ℃;
Maintenance Cycle: :6-12 Months Recommended (Depending on Site Water;
|
After-sales Service: Whole Life Technical Support;
Warranty: One Year;
|
After-sales Service: Whole Life Technical Support;
Warranty: One Year;
Measurement Accuracy: Accuracy: ≤±1% (Current Signal);
Working Mode: Mode: Continuous Monitoring;
Signal Type: 4-20mA Current Signal (3-Wire Gas Detection Device;
Channel Support: 4-20mA Current Signal: Supports up to 64 Channels;
Signal Output: 4-20mA Current Signal Output (Optional);
Recording Details: Alarm Location, Status, Time, Concentration, etc.;
Alarm Limits: A1 (Low Alarm) and A2 (High Alarm) Can Be Set Inde;
Alarm Function: Alarm Indicators: LED Indicator and Buzzer Sound a;
Alarm Output: Output Channels: 2 Sets of Relay Outputs, 2 Adjust;
Contact Capacity: Capacity: Nc: 1/14HP, 125V/250VAC, 25VDC;
Communication Interface: Data Transmission: Supports 4G, Lora, Bluetooth Wi;
Data Recording: Storage: Automatic Storage, Can Store Data with Da;
Data Download: Download Support: Supports Measurement Data Downlo;
Calibration: Calibration Support: Supports 4mA, 12mA, 20mA Thre;
Working Humidity: Humidity Range: 0-95% Rh (No Condensation);
|
After-sales Service: Whole Life Technical Support;
Warranty: One Year;
Sampling Method: Natural Diffusion;
Relative Humidity: <95%;
Pressure Limit: 86kpa~106kpa;
Debugging Method: Infrared Remote Control;
Customized: Customized;
Switch Quantity: 2 (Secondary Alarm Point Is Normally Open);
|
After-sales Service: Whole Life Technical Support;
Warranty: One Year;
Measurement Range: -100°c ~ 20°c;
Accuracy: ≤ ±2°c;
Resolution: 0.01°c;
Response Time: ≤ 5 Minutes (T90);
Power Consumption: < 30W;
Operating Power Supply: 220VAC ± 10%, 50Hz ± 5%;
Isolation Current: (0/4 ~ 20) Ma (500Ω);
Isolation Communication: RS232, RS485 (Optional);
Control Output: Adjustable Passive Contact for Upper and Lower Lim;
Ambient Temperature: (5 ~ 45)°c, Avoid Direct Sunlight;
Permissible Humidity: (0 ~ 85)% Rh;
|