| Specification |
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
OEM: Accept;
Warranty: 12 Months;
Frequency: 50/60Hz;
Power Factor: Cos=0.8;
Primary Current: 30A-3000A;
Secondary Current: 5A or 1A;
Rated Voltage: 0.72kv AC;
Safety Factor: Fs<5;
Short - Time Thermal Current: Ith=60×ih;
Accuracy: 0.5, 1.0, 3.0;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Materials: Epoxy Resin;
PMP: Insulation;
Copper: Input Current;
Silicon Steel Sheet: Protection;
Rated Capacity: 10-35kv;
Ambient Temperature: -20-80;
Coil Number: 2;
Frequency: 50/60 Hz;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Materials: Epoxy Resin;
PMP: Insulation;
Copper: Input Current;
Silicon Steel Sheet: Protection;
Rated Frequency: 50Hz;;
Rated Voltage: 0.5kv-0.66kv;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Materials: Epoxy Resin;
PMP: Insulation;
Copper: Input Current;
Silicon Steel Sheet: Protection;
Rated Frequency: 50Hz;;
Rated Voltage: 0.5kv-0.66kv;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Materials: Epoxy Resin;
PMP: Insulation;
Copper: Input Current;
Silicon Steel Sheet: Protection;
Rated Frequency: 50Hz;;
Rated Voltage: 0.5kv-0.66kv;
|