| Specification |
After-sales Service: Yes;
Warranty: 1;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Maxcapacity: >1000KN;
Accuracy Grade: 0.5;
Load Way: Mechanical Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 500-1000Kg;
Power Source: AC380V;
Oil Cylinder Position: Based on User Needs;
Working Pressure: 21MPa;
Linear Servo Actuator Independent Workin: 0.01Hz-100Hz;
Oscillating Servo Actuator Independent W: 0.01Hz-50Hz;
Compound Working Frequency: 0.01Hz-10Hz;
Effective Torsion Angle: 90°;
|
After-sales Service: Onsite and Remote Guidance;
Warranty: 2 Years Free Warranty Longlife Service;
Type: Universal Testing Machine;
Accuracy Grade: 0.05;
Display: LCD;
Control: Computer Control;
Weight: 1000-2000Kg;
Power Source: AC380V;
Test Capacity: 5000kVA;
Control Mode: Manual/PLC;
Test Items: TTR, Dvdf, Resistance, Hipot and Customized;
Keywords: Transformer Testing System;
Test Console Protection: No Load Test Over-Current Protection Power Frequen;
Key Words: Transformer Testing Equipment;
Temperature Rise Test: Regulator and Ohmmeter with Tempera Rise Function;
Test Object: Distribution Transformers Power Transformers;
Protection: No Load Test Over-Current Protection;
Protection1: Power Frequency Over-Current Protection.;
Protection2: Zero Start Interlock with Auto Return of Regulator;
Protection3: Separate Ground Fault Safety Circuit.;
Protection4: External Interlock Provision.;
Protection5: Emergency Stop Mushroom Button.;
Protection6: Alarm Sound & Light During Test.;
|
Accuracy Grade: 1;
Display: LCD;
Weight: 28kg;
Power Source: AC220V;
Output Voltage: 0.5~12kv;
Cx Accuracy: +-(Read*1%+1PF);
Tg&Delta Accurancy: +-(Read*1%+0.00040);
Internal Hv: 3PF~50000PF/12kv 60PF-1UF/0.5kv;
External Hv: 3PF~1.5UF/12kv 60PF~30UF/0.5kv;
Resolution: Max. 0.001PF, 4 Significant Figures;
CVT Self Excitation LV Output: Output Voltage 3~50V, Output Current 3~30A;
Test Current Range: 10ua~5A;
Setting Voltage Range: 0.5~12kv;
Keywords: C&Df Tester;
Test Frequency: 45, 50, 55, 60, 65Hz Single Frequency;
Test Frequency,Hz: 45/55Hz, 55/65Hz, 47.5/52.5Hz Auto Double Frequenc;
Frequency Precision: +-0.01Hz;
Communiation Port: RS232;
Printer: Build-in Thermal Printer;
|
Accuracy Grade: 1;
Display: LCD;
Control: Computer Control;
Power Source: 110V/220V Can Be Customized;
Peak Voltage: 30kv/40kv/50kv/60kv/70kv/80kv/90kv;
Output Frequency: 0.1Hz, 0.05Hz and 0.02 Hz (Selectable);
Maximum Load Capacity: 1.1UF @0.1Hz, [email protected], [email protected];
Megger Vlf Sinus 62 Kv: up to 90kv at Cutomized;
Power Supply: 220V 230V or at Customized;
Voltage Waveform Distortion: Less Than 5 %;
Output Voltage Accuracy: Peak Voltage Instability Less Than 1%;
Working Environment: Indoor or Outdoor -10-+50, 85%Rh.;
Hv Unit I Weight: 10kg;
Hv Unit II Weight: 22kg;
Capacitor Weight: 2kg;
Adapts: Microprocessor Controlled;
Portable: Easy to Move;
LCD Display: Touch Screen;
Protection: Over Voltage and Current Protection;
|
After-sales Service: Remote Guidance;
Warranty: 1or 2 Years Free Warranty Longlife Service;
Type: Universal Testing Machine;
Accuracy Grade: 0.01;
Display: LCD Touch Screen;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: 110V/220V Can Be Customized After Place Order;
Phase: 12;
Test: Time,Velocity, Trip;
Color LCD: Touch Screen;
Language: English;
Printer: Build-in;
Data Storage: 6000 Groups (Memory Card Is Extendable);
Communicate: USB Port;
External Trigger Voltage: AC/DC10-300V, Current Less 120A;
AC Source: AC 220V 20%, 50Hz 2% (Can Be Customized);
DC Source Output Voltage: 15-265V Continuous Adjustment;
DC Source Output Current: 20A(Short Time);
Time Test: 12 Channels;
Velocity Test: Open(Close)Velocity;
Travel Test: Moving Contactor Travel;
Accuracy Rate Within 200ms: 0.05%;
|