| Specification |
Type: RFID Module;
Card Type: CPU, EM, Tk4100 Em4305;
Interface: USB, Serial Port, RS232/RS485/Wg26/34;
Reading Distance: >8cm;
Application: Hospital, Library, Company, Bank, Store;
Name: 125kHz & 13.56MHz RFID Module;
Frequency: 125kHz, 13.56MHz;
Support Chips: Em4200/Tk4100/T5577/Em4305, NFC, UL etc;
Power Supply: 5V or 3.3V;
Protection Level: IP65;
Protocol: ISO14443A/B, ISO15693 & ISO18092;
Software: Supply Sdk&Demo for Free;
Antenna: External, Variety of Optional Specifications;
Sample: Free;
Connection: Metal Pin Connection;
Reading Range: 0-8cm;
Read/Write: Read Uid Only;
Supporting Card: Em4200/Tk4100;
ODM/OEM: Accept;
|
Type: Access Control Board;
Card Type: CPU, HID, Mifare, EM, IC/ID;
Interface: USB;
Reading Distance: 100m;
Application: Parking, Hospital, Library, Company, Bank, Store, Office;
Communication: TCP/IP 10m/100m Adaptive(Extension RS485);
Input Format of Reader: Wiegand2634(All Card Reader with Compatible Protoc;
Number of Inputs: 16ea(4 Exit Button, 4 Door Sensor, 4 Wiegand;
Number of Outputs: 5 Form-C Relay Output(4 Lock, 1 Alarm);
Max Distance From Reader to Controller: 100m (Suggestion Distance 80m);
Collocations: PCB Board, Case, Power, Power Line, Serial Port Co;
Operation Humidity: 10-90%Rh, No Condensation;
Max Q ' Ty of Controller: No Limit;
Q ' Ty of Users: 20, 000 Users;
Q ' Ty of Event Buffers(Offline): 70, 000 Event Buffers;
Quantity of Readers: 4 PCS;
Size of PCB Board: L273xw175xh72mm;
|
Type: IC Card Reader;
Card Type: EM;
Interface: USB;
Reading Distance: 5~30cm;
Application: Livestock, Animal, Pet;
Procotol: ISO 11784/785;
Frequency: 134.2kHz;
Standard: Fdx-B and Hdx;
Read Distance: 5~30cm;
|
Type: Access Control Board;
Card Type: CPU, HID, Mifare, EM, IC/ID;
Interface: USB;
Reading Distance: 100m;
Application: Parking, Hospital, Library, Company, Bank, Store, Office;
Communication: TCP/IP 10m/100m Adaptive(Extension RS485);
Input Format of Reader: Wiegand2634(All Card Reader with Compatible Protoc;
Quantity of Readers: 2 PCS;
Number of Inputs: 8ea(2 Exit Button, 2 Door Sensor;
Number of Outputs: 3 Form-C Relay Output(2 Lock, 1 Alarm);
Max Distance From Reader to Controller: 100m (Suggestion Distance 80m);
Max Distance Between Controllers: RS232: Communication Distance Less Than 13m, Sugge;
Collocations: PCB Board, Case, Power, Power Line, Serial Port Co;
Alarm for Long Time Door Open, Ilegal Br: Yes;
Power Consumption of Circuit Board: Less Than 100mA;
Power Supply: DC12V/400mA;
Size of PCB Board: L330xw288xh72mm;
|
Type: Access Control Board;
Card Type: CPU, HID, Mifare, EM, IC/ID;
Interface: USB;
Reading Distance: 100m;
Application: Parking, Hospital, Library, Company, Bank, Store, Office;
Communication: TCP/IP 10m/100m Adaptive(Extension RS485);
Input Format of Reader: Wiegand2634(All Card Reader with Compatible Protoc;
Quantity of Readers: 2 PCS;
Number of Inputs: 8ea(2 Exit Button, 2 Door Sensor;
Number of Outputs: 3 Form-C Relay Output(2 Lock, 1 Alarm);
Max Distance From Reader to Controller: 100m (Suggestion Distance 80m);
Max Distance Between Controllers: RS232: Communication Distance Less Than 13m, Sugge;
Collocations: PCB Board, Case, Power, Power Line, Serial Port Co;
Alarm for Long Time Door Open, Ilegal Br: Yes;
Power Consumption of Circuit Board: Less Than 100mA;
Power Supply: DC12V/400mA;
Size of PCB Board: L330xw288xh72mm;
|