| Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Single-Phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Intermediate Frequency;
Shape of Core: U;
Brand: Grewin;
Accuracy Class: Class 0.1, 0.2;
Operating Temperature:-25 to +55 Degree: Retardant Rating 94-V0;
Frequency:50 to 400 Hz: Accuracy Class:as Defined in IEC 60044-1;
Color: Blue, Black, Yellow, White;
Applications: Precision Watt-Hour Meter;
Use for: Electric Energy Measurement;
|
Application: Electronic, Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Electronic, Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Electronic, Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|