| Specification |
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Measuring Medium: Temperature;
IP Rating: IP68;
Customized: Customized;
Item: Refrigerator Temperature Transmitter Probe;
Color: Common Color Is Ok;
Tolerance: 0.1%-5%;
Theory: Resistance Thermometer;
Length: as Customer Request;
|
Installation Type: Portable;
Sensing Type: Sensirion Sht30;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Injection;
Material: Alumina;
Measuring Medium: Temperature and Humidity;
IP Rating: IP64;
Customized: Customized;
Monitoring Information: Temperature, Humidity, Location, Light, Vibration;
Temperature Measurement Range: -20℃~ +60℃;
Temperature Accuracy Range: ±0.3℃ (0℃ ~ +60℃); ±0.5℃ for Other Range;
Humidity Measurement Range: 5%~95%Rh;
Humidity Accuracy Range: ±3%(10%~90%Rh); ±5% for Other Range;
Light Sensor Range: 0-64000lux;
Vibration Sensor Range: 0-16g;
Minimum Unit: 0.1℃/0.1%Rh/1 Lux/0.001g;
Position Type: Lbs Base Station Position;
Memory Capacity: 17,000;
Network System: Global LTE 4G, with 2g Fallback;
Recording Interval: Default 15min , Configurable;
Reporting Interval: Default 60min , Configurable;
Usage Time: Once Fully Charged, It Can Be Used for 120 Days Ba;
Battery Specification: Bulit-In3.7V/4000mAh Lithium Rechargeable;
|
Installation Type: Portable;
Sensing Type: Sensirion Sht30;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Injection;
Material: Alumina;
Measuring Medium: Temperature and Humidity;
IP Rating: IP64;
Customized: Customized;
Monitoring Information: Temperature, Humidity, Location, Light, Vibration;
Temperature Measurement Range: -20℃~ +60℃;
Temperature Accuracy Range: ±0.3℃ (0℃ ~ +60℃); ±0.5℃ for Other Range;
Humidity Measurement Range: 5%~95%Rh;
Humidity Accuracy Range: ±3%(10%~90%Rh); ±5% for Other Range;
Light Sensor Range: 0-64000lux;
Vibration Sensor Range: 0-16g;
Minimum Unit: 0.1℃/0.1%Rh/1 Lux/0.001g;
Position Type: Lbs Base Station Position;
Memory Capacity: 17,000;
Network System: Global LTE 4G, with 2g Fallback;
Recording Interval: Default 15min , Configurable;
Reporting Interval: Default 60min , Configurable;
Usage Time: Once Fully Charged, It Can Be Used for 120 Days Ba;
Battery Specification: Bulit-In3.7V/4000mAh Lithium Rechargeable;
|
Installation Type: Duct Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: RS485/4-20mA/0-5V/0-10V;
Production Process: Integration;
Material: Metal;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Working Environment: -40℃~+60℃, 0%Rh~95%Rh (Non-Condensing);
Temperature Range: -40℃~+80℃, (-40℃~+120℃ Optional);
Humility Range: 0%Rh~100%Rh;
Temperature Display Resolution: 0.1℃;
Humidity Display Resolution: 0.1rh%;
Humidity Accuracy: ±3%Rh (60%Rh, 25℃);
Temperature Accuracy: ±0.5℃ (25℃);
|
Installation Type: Duct Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: RS485/4-20mA/0-5V/0-10V;
Production Process: Integration;
Material: Metal;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Working Environment: -40℃~+60℃, 0%Rh~95%Rh (Non-Condensing);
Temperature Range: -40℃~+80℃, (-40℃~+120℃ Optional);
Humility Range: 0%Rh~100%Rh;
Temperature Display Resolution: 0.1℃;
Humidity Display Resolution: 0.1rh%;
Humidity Accuracy: ±3%Rh (60%Rh, 25℃);
Temperature Accuracy: ±0.5℃ (25℃);
|