| Specification |
Measuring Medium: Temperature;
Site Display: Not Site Display;
Customized: Customized;
Item: DIN Temperature Signal Isolated Converters;
Rtd Type: PT100, PT10, Cu100, Cu50;
Input Temperature Range: -20-10, 0-100, 0-150, 0-200, 0-400;
Output: 4-20mA, 0-20mA, 0-5V, 0-10V, 1-5V, -20-20mA;
Isolation Voltage: 3000VDC;
Power Supply: 24V/12V/15V/5VDC;
Package Methods: DIN Rail Mounted;
Industrial Temperature Range: -45~+85 Centigrade;
Standard Packaging: DIP 24/SIP12 Pin, DIN35 Rail-Mounted;
Lead Time: 3-4 Days;
Warranty: 2 Years.;
Shipping Way: DHL /FedEx/ TNT etc;
Shipping Time: 3-5 Working Days;
Payment Way: T/T, Paypal;
Keywords: Temperature Signal Isolator;
|
Type: Network Type;
Measuring Medium: Temperature;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.2;
IP Rating: IP67;
Customized: Customized;
Place of Origin: China;
Warranty: 1 Year;
Model: 644;
Customized Support: OEM;
Brand Name: Rosemount;
Product Type: Temperature Transmitter Module;
Input Type: Rtd, Thermocouple, Ohm, Millivolt;
Output Signal: 4-20 Ma Hart;
Measurement Range: -200°c to 850°c (-328°f to 1562°f);
Power Supply: 10.5-55 V DC;
Enclosure Rating: IP66, IP67;
Certifications: CE, FM, ATEX, Iecex;
Mounting Style: DIN Rail or Panel Mount;
Housing Material: Aluminum or Stainless Steel;
Display: Optional LCD;
|
Type: Temperature Sensor;
Measuring Medium: Temperature;
Site Display: Not Site Display;
IP Rating: IP65;
Customized: Customized;
Sensor Core: PT100;
Housing: SS304;
Magnet Grade: N35 by Default. N45h or Others on Demand;
Electronic Connection: 1.5 Meters Cable Outlet, 2,3,or 4 Wires on Demand;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.2;
IP Rating: IP20;
Customized: Customized;
Storage Humidity: 10 ~ 95% (No Condensation);
Operating Humidity: 10 ~ 90% (No Condensation);
Storage Temperature: -45 ~ +80 ºC;
Operating Temperature: -40 to +85 ° C;
Impact Resistance Voltage: 3kv, 1.2/50us (Peak Value);
Isolation Voltage: 2500VDC, 1 Minute, Leakage Current (1mA);
Isolation: Input / Output / Auxiliary Power Isolation;
Current Output: ≤ 450ω;
Load Capacity: Voltage Output: ≥ 2 kΩ;
Temperature Drift: 50ppm / ºC (Typical);
Power: <1W;
|
Type: Network Type;
Measuring Medium: Humidity;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.2;
IP Rating: IP20;
Customized: Customized;
Accuracy1: 0.2% (Relative to Temperature);
Input: Three-Wire, Four-Wire or Two-Wire Rtd Signal,;
Output: Standard Voltage or Current Signal. Can Also Be Us;
Response Time: ≤ 100ms;
Auxiliary Power: DC5V, 9V, 12V, 15V, 24V;
Power: <1W;
Temperature Drift -: 50ppm / ºC (Typical);
Load Capacity: Voltage Output: ≥ 2 kΩ;
Current Output: ≤ 450ω;
Isolation: Input / Output / Auxiliary Power Isolation;
|