| Specification |
Installation Type: Wall-Mounted Type;
Sensing Type: Resistive;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Integration;
Measuring Medium: Temperature;
IP Rating: IP68;
Customized: Customized;
R25 Value: 1K, 2K, 2.252K. 5K, 10K, 50K,100K;
Tolerance: 1%, 2%, 3%, 5%;
B Value: 3380K~4200K;
Probe: Plastic, or Customized;
Operation Temp: -45c~120c;
Cable: Teflon Wire,PVC Wire,Silicone Wire, or Customized;
Length: 100mm,500mm,1m,,2m,5m or Customized;
Connector: 3.5 Jack,Tjc3 2.54, Smr,5566 or Customized;
Usage: Floor Heating, Air Conditioner, Refrigeration;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Normal Wirewound;
Material: Carbon Humidity;
Measuring Medium: Temp, Humidity and Pressure;
IP Rating: IP65;
Customized: Customized;
Temp Range: -40-60℃;
Humidity Range: 0-100%Rh;
Pressure Range: 10-110kpa(100-1100mbar);
Output: 4-20mA,0-10V,RS485, Iic,SDI-12;
Supply: 5VDC, 12-24VDC;
Current Consumption: <20mA;
Radiation Shield(Optional): Rk95-01,11 Plates,M25*1.5;
Cable Length: 1.5m Standard;
Operating Temperature: -40℃-+80℃;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Normal Wirewound;
Material: Carbon Humidity;
Measuring Medium: Temp, Humidity and Pressure;
IP Rating: IP65;
Customized: Customized;
Temp Range: -40-60℃;
Humidity Range: 0-100%Rh;
Pressure Range: 10-110kpa(100-1100mbar);
Output: 4-20mA,0-10V,RS485, Iic,SDI-12;
Supply: 5VDC, 12-24VDC;
Current Consumption: <20mA;
Radiation Shield(Optional): Rk95-01,11 Plates,M25*1.5;
Cable Length: 1.5m Standard;
Operating Temperature: -40℃-+80℃;
|
Installation Type: Bury in The Soil;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Integration;
Material: Alumina;
Measuring Medium: Temperature;
IP Rating: IP68;
Customized: Customized;
Range: 0-14pH;
Output Signal: 4-20mA ,0-5V,0-2V,RS485;
Supply: 5VDC, 12-24VDC;
Ingress Protection: IP68;
Cable Length: 2m Standard;
Testing Medium: Water or Soil;
|
Installation Type: Bury in The Soil;
Sensing Type: Resistive;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Ceramics;
Material: Alumina;
Measuring Medium: Temperature;
IP Rating: IP68;
Customized: Customized;
Range: 0-50%,0-100%;-30c-+70c;0-5000us/Cm,10000us/Cm(Type;
Output Signal: Analog Voltage 0-2V,RS485 Modbus RTU,Sdl-12;
Supply: 3.6-30VDC,5-24VDC(SD1-12);
Ingress Protection: IP68;
Power Consumption: 6mA@12VDC;
Measurement Technique: Moisture by Fdr and Ec by AC Excitation;
|