| Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Rated Voltage: 0.66kv;
Insulation Voltage: 3kv;
Rated Frequency: 50/60Hz;
Operating Temperature: -15℃TO 60℃;
Certificates: CE,UL.RoHS;
Input (a): 0.2-120AAC;
Max Currnet (a): 140AAC;
Color: Black ,White ,Blue;
MOQ: 10 PCS;
Lead Time: 3-7 Days;
Wire Cable: Twist ,Sheath or Others;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Product Name: Current Transformer;
Model: H-CT005-16D;
Rate Current: 100A;
Max Current: 120A;
Secondary Current: 333mv;
Winding Ratio: 1:3000;
Diameter: 16mm;
Wire Length: 100mm;
Net Weight: Approx 105g;
ODM: Customization;
OEM: Customization;
RoHS: Customization;
Supply: Jiaxing Haihan Electron Co., Ltd;
|
Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Frequency: 50Hz;
Rated Voltage: 12kv;
Rated Current: 630A;
|
Application: Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv,7.2/30/60kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Outdoor;
|