| Specification |
After-sales Service: Maintenance & Refund;
Warranty: Maintenance & Refund;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
Measuring Range: 0.1...14000ppm;
Accuracy: ±5% F.S.;
Temperature Range: 0...60 Deg.C;
Response Time: 90% Less Than 90 Seconds;
Pressure Range: 0-3 Bar;
Shell Material: PC Plastic + 316L Stainless Steel;
Output: 4-20mA RS 485 (Mod_Bus RTU);
Power Supply: DC 9-30V (Std DC 12V);
Pipe Thread: G 3/4" + G 1" Male Thread;
Cable Length: 5m or Customized;
Protection: IP68;
Installation: Immersion Type & Flow Through;
Sensor Type: PVC Membrane;
Electrode Resistance: 0-4 MΩ;
Keywords: Industrial Chloride Ion Selective Sensor;
|
After-sales Service: Yes(Except The Consumbles);
Warranty: 1 Year;
Display: Digital;
Appliance: Biochemistry;
Burette Repeatability: 0.20%;
Burette Accuracy: 10ml Burette: 0.025ml; 20ml Burette: 0.035ml;
Burette Resolution: 10ml Burette: 1/20000; 20ml Burette: 1/10000;
Measuring Range: (-1999.0~1999.0) Mv, (0.00~14.00)pH;
Measuring Resolution: 0.1mv, 0.01pH;
Temp. Compensation: (-5.0~105.0) Degree;
Power Supply: AC Adapter, 100-240V AC Input, DC24V Output;
Dimension: 340*400*400mm;
Weight: 10kg;
|
After-sales Service: Supply Free Part for Quality Problem in Warrant;
Warranty: 1year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
R&D Capacity: OEM/ODM;
pH Range: -2.00 to 20.00 pH;
pH Resolution: 0.1,0.01,0.001pH;
pH Accuracy: ±0.002 pH;
pH Calibration Points: up to 6;
pH Standard Recognition: Nist, GB, DIN, USA, Merk, JIS Buffers;
Mv Range: -2000.0 to 2000.0 Mv;
Mv Resolution: 0.1, 0.01 Mv;
Mv Accuracy: ±0.1 Mv or ±0.03%;
Temperature Range: -10 to 135 ℃, 14 to 275 ℉;
Temperature Unit: ℃, ℉;
Temperature Resolution: 0.1;
Temperature Accuracy: ±0.1℃;
Measurement Reading Prompts: Reading, Stable, Locked;
Temp. Compensation: Atc, Mtc;
|
After-sales Service: Supply Free Part for Quality Problem in Warrant;
Warranty: 1year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
R&D Capacity: OEM/ODM;
pH Range: -2.00 to 18.00 pH;
pH Resolution: 0.01pH;
pH Accuracy: ±0.01 pH;
pH Calibration Points: up to 3;
pH Standard Recognition: Nist Buffers;
Mv Range: -1999 to 1999 Mv;
Mv Resolution: 1 Mv;
Mv Accuracy: ±0.1%Fs;
Temperature Range: -5 to 110 ℃;
Temperature Unit: ℃;
Temperature Resolution: 0.1℃;
Temperature Accuracy: ±0.2℃;
Measurementtreading Mode: Auto Read, Continuous;
Measurement Reading Prompts: Reading, Stable, Locked;
|
After-sales Service: Supply Free Part for Quality Problem in Warrant;
Warranty: 1year;
Display: Digital;
Portable: Non Portable;
Appliance: Food Analysis, Medical Research, Biochemistry;
R&D Capacity: OEM/ODM;
pH Range: 0.00 to 14.00 pH;
pH Resolution: 0.01pH;
pH Accuracy: ±0.01 pH;
pH Calibration Points: up to 2;
pH Standard Recognition: Nist Buffers;
Mv Range: -1800 to 1800 Mv;
Mv Resolution: 1 Mv;
Mv Accuracy: ±0.1%Fs;
Reading Mode: Continuous;
Temp. Compensation: Mtc;
pH Electrode: BNC(Q9);
Auto Shutdown: 300, 600, 1200, 1800, 3600 Sec., off;
IP Rating: IP54;
Power: AC Adapter, 100-240V AC Input, DC9V Output;
|