| Specification |
After-sales Service: 24-hour online service,free accessories;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: NIR Spectrophotometer;
Customized: Customized;
Spectral Bandwidth(nm): 12;
Measurement Mode: The diffuse reflection sample cell;
Wavelength Range: 900-2500 nm;
Analysis Time: 1min (adjustable);
Power Supply: 90-250V\50Hz (or 60Hz);
|
After-sales Service: /;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
Model: Bk-V1000g;
Color: White;
Warranty Time: One Year;
Optical System: Single Beam, Grating 1200L/mm;
Wavelength: 200-1020nm;
Spectral Bandwidth: 4nm;
Wavelength Accuracy: ±1.5nm;
Wavelength Repeatability: ≤0.2nm;
Photometric Accuracy: +0.002ABS (0-0.5ABS);
Photometric Repeatability: 0.001ABS(0-0.5ABS),;
Stray Light: ≤0.1%T(220nm,360nm);
Stability: ±0.001A/H(500nm);
Photometric Mode: a T C E;
Wavelength Setting: Auto;
Gross Weight: 14.4kg;
|
After-sales Service: Repair Service and Free Parts Replacement;
Application: Laboratory Apparatus;
Warranty: 1.5 Years;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: UV/Vis;
Dispersive Element: Interferometer Spectrometer;
Light Number: Polychromator;
Customized: Customized;
Product Name: Single Beamuv/Vis Spectrophotometer;
Model: Bk-UV1600g;
Optical System: Single Beam, Grating 1200L/mm;
Wavelength: 190~1100nm;
Spectral Bandwidth: 4nm;
Wavelength Accuracy: ±1.5nm;
Wavelength Repeatability: ≤0.2nm;
Photometric Accuracy: +0.002ABS (0-0.5ABS), ±0.004A (0.5-1.0ABS);
Photometric Repeatability: 0.001ABS(0-0.5ABS), 0.002ABS(0.5-1.0ABS);
Stray Light: ≤0.05%T(220nm, 360nm);
Stability: ±0.001A/H(500nm);
Photometric Range: -0.301-3.0A 0-200%T 0-9999c;
Photometric Mode: a T C E;
Wavelength Setting: Automatic;
Detector: Imported Silicon Photodiode;
|
After-sales Service: Repair Service and Free Parts Replacement;
Application: Laboratory Apparatus;
Warranty: 1.5 Years;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Fluorescence Spectrophotometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Product Name: Fluorescence Spectrophotometer;
Model: Bk-F96PRO;
Light Source: Hamamatsu 150W Xenon Lamp;
Exciting Optical Filters: Interference Optical Filter a) Standard Set Is EQ;
Emission Monochromator: C-T Diffraction Grating Em 200~900nm, Bandwidth 10;
Wavelength Accuracy: ±1nm;
Wavelength Repeatability: ≤0.5nm;
Sensitivity: Raman Peak of Water in 1 Cm Quartz Fluorescence Cu;
Linear Measurement(R): ≥0.995;
Stability: Better Than 1.5%/10min;
Response Time: (0.1~4)S 6 Stages Adjustable;
Fluorescence Display Value: 0.00~600.00;
Power Supply: AC110/220V±10%, 60/50Hz;
Packing Size(mm): 550*510*365;
Gross Weight(Kg): 14;
|
After-sales Service: Repair Service and Free Parts Replacement;
Application: Laboratory Apparatus;
Warranty: 1.5 Years;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Aas;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Product Name: Atomic Absorption Spectrophotometer;
Model: Bk-AA4530f;
Wavelength Range: 190~900nm;
Spectral Bandwidth: 0.1, 0.2, 0.4,1.0 and 2.0nm;
Wavelength Accuracy: ≤±0.15nm;
Wavelength Repeatability: ≤0.04nm;
Base Line Stability: ≤0.002A/30min (Cu);
Characteristic Concentration: 0.02μg/Ml/1% (Cu);
Detection Limit: 0.004μg/Ml (Cu);
Preciseness: ≤0.5%;
Grating: 1800 Lines/mm;
Inflamer: All-Metal Titanium Burner;
Atomizer: Effective Glass Atomizer;
Lamp Stand: 8;
Power Supply: 220/110V, 50/60Hz;
|