| Specification |
Display: LCD;
Control: Computer Control;
Weight: 10kg;
Power Source: AC 110V/220V at Customized;
Time Test: 6 Channels (12 Channels for Option);
Data Storage: 100 Groups;
Test Range: 0.1ms~999.99ms;
|
After-sales Service: Lifetime;
Warranty: 1 Year;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Type: Fatigue Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: PC;
Control: Computer Control;
Weight: 100-500Kg;
Power Source: AC380V;
Oil Cylinder Position: None;
Maximum Test Force: 25 kN;
Frequency Range: 0.1-30Hz;
Force Accuracy and Fluctuation: 1%;
Accessories: Customer Requirements;
|
Warranty: 12 Months;
Type: Load Bank;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 1000-2000Kg;
Power Source: AC380V;
Cooling: Forced Air Cooling;
Frequency: 50/60Hz;
Contactor: Schneide-R;
Color: Blue Ral5015 and White;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|