| Specification |
Classification: Clinical Urodynamic Analyzer;
Type: Urodynamic Detection System;
Group: All;
Material: High Tech Materials;
Function: Clinical Analysis Instrument;
Product Category: Medical Diagnosis Equipment;
Product: Clinical Urodynamic System;
Pressure Measuring Range: Pressure: -50CMH20(-4.9kpa)~200CMH20(19.6kpa) Erro;
MOQ: 1PC;
|
Classification: Biological Diagnostics;
Type: Automatic Biochemistry Analyzer;
Group: All;
Product Name: Automatic Biochemistry Analyzer;
Throughput: 200 Tests/Hour;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Sample Positions: 37 Sample Positions;
Reagent Position: 28 Reagent Positions;
Sample Volume: 2~70μl;
Reagent Volume: 20~350μl;
Probe: Liquid Level Sensor Function, Anti-Collision Funct;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Temperature Control: 37+0.1℃, Real-Time Monitoring;
Cuvettes: 48 Reusable Cuvettes,Optical Length 6mm;
Light Source: 6V/10W Halogen Lamp;
Spectrophotometry: Post-Spectral Spectrophotometry;
Wavelength: 340,405,450,510,546,578,630,700nm;
|
Classification: Biological Diagnostics;
Type: Chemistry Analyzer;
Group: All;
Product Name: Auto Chemistry Analyzer;
Test Speed: 220t/H;
Analysis Method: End-Point, Fixed-Time, Rate, Turbidimetry;
Sample Positions: 49 Sample Positions, Including Calibration, Quali;
Reagent Positions: 56 Refrigerated Reagent Positions;
Sample Volume: 2UL ~70UL (0.1UL Stepping);
Reagent Volume: R1 & R2: 20UL ~350UL (1UL Stepping);
Sample & Reagent Probe: Liquid Level Sensor Function, Anti-Collision Func;
Probe Washing: Automatically Wash Interior and Exterior;
Reaction Time: 10 Minutes;
Cooling Function: 2ºC~8ºC Cooling for 24 Hours;
Temperature Control: 37ºC±0.1ºC, Real-Time Monitor;
Receiver: 8 Precision Photo Receivers;
Linear Range: 0.000~3.000ABS;
Computer System: Windows7/8/10, Lis System Available;
|
Classification: Biological Diagnostics;
Type: Automatic Chemiluminescence Immunoassay System;
Group: All;
Throughput: 120t/H;
Principle: Magnetic Particle Enzymatic Chemiluminescence;
Modes of Operation: Random, Batch and Stat;
Separation Method: Magnetic Separation Technology;
Sample Positions: 60 (Each Position Could Be Used as an Emergency Po;
Reagent Positions: 30 PCS (2-8℃ Refrigeration);
Incubation Positions: 80;
Time to 1st Result: 18 Minutes;
Sample Volume: 15-100UL;
Carry-Over Rate: Less Than10-5;
Calibration Stability: 28 Days;
Calibration Type: 6/7-Point Calibration;
Software System: Windows 7/8/10, 32 or 64 Bit;
Interface: TCP/IP Network Interface;
Power Supply: AC110/220V,50/60Hz;
|
Classification: Biological Diagnostics;
Type: Elisa Microplate Washer;
Group: All;
Product Name: Elisa Microplate Washer;
Model: Bk-9622;
Microplate Types: Applicable to All Types of Microplates. Flat Botto;
Washingmode: 2 Kinds Ofautomatic Washing,Soaking Andshaking, to;
Average Residue: <1μL;
Number Ofmicroplate: 1- 12 Rows Adjustable;
Cleaninghead: 8 Channels and 12 Channels;
Liquidsuctiontime: 0.1-9.9 Seconds Adjustable, with an Interval of 0;
Washingprograms: up to 100 Programs;
Flushingpipeline Time: 0-240 Seconds Adjustable;
Display: 5.0 Inch LCD Screen;
Liquidinjectionchannels: 3 (2 Types of Lotion and 1 Type of Distilled Water;
Cleaningneedleposition: 5 Types Adjustable (Horizontal,Left,Center,Right,;
Packing Size(W*D*H): 710*510*451mm;
Gross Weight: 23kg;
|