| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Rail Type;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Current: 63A;
Operating Breaking Capacity: 10ka;
Poles: 2p;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Timelec;
Poles Number: 3;
Type: Timelec;
Function: Timelec;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 80A,125A,160A,250A,400A,500A;
Trip curve: B, C, D;
Energy limiting class: 3;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection, RCCB;
Standard: GB16916-1 & IEC 61008-1;
Tripping Curve: B,C;
Rated Current (in): 25A,40A,63A,80A;
Residual Current Type: Type AC,A,B;
Residual Current (LΔn): 30mA,100mA,300mA;
Making Breaking Capacity (IΔm): 2,000A;
Energy Limiting Class: 3;
|