| Specification |
After-sales Service: Changing or Refunding;
Warranty: 1 Year;
Accuracy: >±1%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas, Steam;
Size: DN15~DN300 or Above;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Gas;
Measuring Principle: Karman Vortex Street;
Measurement Object: Closed Pipeline;
Medium Temperature: -40 ℃ ~ 350 ℃;
Ambient Temperature: -20 ℃ ~ 70 ℃;
Pressure Rating: 1.6MPa, 2.5MPa, 4.0MPa, 6.3MPa, or Customized;
Body Material: SS304, SS316, etc.;
Connection Way: Flange, Clamp, Insertion, Threaded, etc.;
|
After-sales Service: Technical Support;
Warranty: 1;
Accuracy: >±1%;
Main Application: Nature Gas, Corrosive Liquid/Gas;
Size: DN10-50;
Sensor: Plug-in;
Application: Industrial Production;
Type: Volume Type Flow Meter;
Measuring Media: Gas;
Measuring Principle: Thermodynamic;
Measurement Object: Closed Pipeline;
Power Supply: DC24V or AC220V;
Working Pressure: Medium Pressure Less Than 4.0MPa;
Response Speed: 1s;
Pipe Material: Carbon Steel, Stainless Steel, Plastic, etc;
Output Signal: 4-20mA, Pulse, RS-485, Hart;
Ingress Protection: IP65;
|
After-sales Service: on Line;
Warranty: 12 Months;
Accuracy: 0.1-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN100-500;
Sensor: Clamp-on/External;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Open Channel;
Product Name: Coriolis Mass Flowmeter Flow Instrument for Hydrog;
Key Word: Coriolis Mass Flowmeter Flow Instrument for Hydrog;
Temperature: Low Temperature;
Pressure: High Pressure;
Special Medium: Gases with Minimal Liquid Content;
Measure Parameters: Mass Flow, Temperature, Density, Volume Flow;
|
After-sales Service: 12months;
Warranty: 12months;
Accuracy: ±0.2-0.5%;
Main Application: Diesel Fuel, Fuel Oil;
Size: DN10-50;
Sensor: Tube/Flange;
Application: for Gas Station;
Type: Ogm Flow Meter;
Measuring Media: Gas;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Material: Stainless Steel/Cast Iron/Aluminum;
Medium: Non Corrosive Liquid;
Connection: Thread/Flangle;
Working Pressure: 1.0MPa/150psi;
Viscosity: 30ssu~1,500,000ssu;
|
After-sales Service: on Line;
Warranty: 12 Months;
Accuracy: 0.1-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN100-500;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Open Channel;
Product Name: Coriolis Mass Flowmeter for CNG Dispenser with Ate;
Key Word: Mass Flow Meter;
Measurement Method: Directly Measure Mass Flow;
Measurement Accuracy Affected Factor: Only by Vibration;
Special Medium: Gases with Minimal Liquid Content;
Measure Parameters: Mass Flow, Temperature, Density, Volume Flow;
Installation Requirements: No Need to Consider Upstream and Downstream;
Measurable Medium: High-Viscosity , Liquids with Trace Solids;
|