| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: DC MCB;
Votage: 440V 550V 800V 1000V 1200V 1500V;
Ampes: 6,10,16,20,25,32,40,50,63A;
Pole: 4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Rated Voltage: 240V AC;
ICU: 6ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 2p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO;
Rated Voltage: 230/400V AC;
Inc: 6/10ka;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Phase: 1/2/3;
Main Circuit Rating Voltage: 36KV;
Main Circuit Rating Current: 2000A;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Normal Type Circuit Breaker;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Handcart/Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Handcart/Fixed;
Name: Vacuum Circuit Breaker;
Color: Red/Black/White;
Rated Voltage: 12kv;
Rated Current: 630-1600;
Certufucates: ISO;
|