| Specification |
Classification: Imaging Diagnostic Equipment;
Type: X Ray Equipment;
Group: Middle-aged and Old;
Power Source: Electrical;
Material: Metal, Plastic, Steel;
Internal Resistor: ≤0.17Ω;
Tube Current: 10mA-630mA Step Regulation;
After-Sale Service: Online Technical Support;
Power Output: 50kw;
Safety Standard: None;
Capacity: >65kVA;
Voltage: 380V;
Inverter Frequency: 200kHz;
Frequency: 50Hz;
Shelf Life: 1 Year;
Exposure Time: 1ms-6300ms Step Regulation;
Tube Voltage: 40kv-150kv Step Regulation;
Mas: 0.1-630mas;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Hematology Analyzer;
Group: All;
Model: Bk-6310;
Throughput: 60 Tests/Hour;
Measuring Principle: Coulter Principle Colorimetry Hemoglobin Determin;
Parameters: Wbc, Ly#, MID#, Gr#, Ly%, MID%, Gr%, Rbc, Hgb, H;
Histograms: 5 Histograms (Including Wbc, Rbc, Plt);
Sampler Volume: Predilute 20μl Whole Blood 10μl;
Display: 8” Color Touch Screen Display;
Intelligent Reagent Management Function: Reagent Information and Residual Display;
Printer: External Printer;
Input and Output: 1 RS232, Keyboard, Mouse, 4USB, LAN;
Option: Barcode Scanner, Lis;
Operating Environment: Temperature 10-35 Oc Humidity≤90%;
Power Supply: AC110/220V±10%, 60/50 Hz;
Package Size(mm): 630*600*700;
Gross Weight(Kg): 25;
|
Classification: Biological Diagnostics;
Type: Elisa Processor;
Sample Racks: 80 Sample Positions(Tubes 13mm);
Pipetting: 10~1000UL;
Dispensing System: 1 Aspirating-Dispensing Probe with X-Y-Z Movement;;
Reagent Racks: 8+1reagent Racks, Editable;
Pipetting Range: 10~1000UL,1UL Stepping;
Pipetting Precision: (100UL) CV≤0.5%;
Dispensingtime: 5 Minutesto Whole96well Microplates;
Incubation: 2 Independentincubators;
Temperature Range: Rt to 45 °c;
Washingprobes: Two Line 8-Nozzle Manifolds;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Display: 4.3'';
Wavelength: LED 470nm;
Sample Type: Plasma;
Results: 10000 Results Storage;
Sample Volume: 20-40μl;
Incubation Temperature: 37.0±1.0℃;
Relative Humidity: ≤85%;
Precision: PT, Aptt, Fib≤5%; Tt≤8%(Normal Sample);
Deviationbetween Channels: ≤5%;
Power Supply: AC100~240V, 50/60Hz;
External Size: 290*260*135mm;
Net Weight: 2.1kg;
Package Size: 7kg;
Grossweight: 38kg;
Color: White-Blue;
|
Classification: Biochemical Apparatus;
Type: Incubator;
Group: All;
Product Name: Climate Incubator;
Package Size(W*D*H): 780*690*1350;
Internal Size(W*D*H): 500*380*790;
External Size(W*D*H): 680*590*1250;
Capacity: 160L;
Lighting Type: Two-Sided Lighting, Three-Sided Lighting (Optional;
Language: English;
Temp.Resolution: 0.1 C;
Temp.Fluctuation: 1.0c;
Temp.Control Range: with Illumination: 10~50 C,;
Humidity Control Range: 50~95%Rh;
Brand Name: Biobase;
Warranty: 1 Year;
Instrument Classification: Class II;
After-Sale Service: Online Technical Support;
|