| Specification |
Sensing Method: Slot Reader;
Application: Access Control System;
Movement: Single Movement;
Type: Swing Gate;
Control Mode: Automatic;
Communication Interface: RS485, TCP/IP;
Direction: Dual Direction;
Speed: 40 Per/ Min;
Open Speed: 0.2s;
Passage Width: 600-900mm;
Funtion: Security;
Motor: Brushless DC Motor;
Infrared Sensor: 6 Pairs;
Function: Anti Trailing;
Open Method: Face Recognition Device, Finger Print Device;
Working Temperature: -25c ~ 70c;
Power Supply: 220V , 380V;
Service Life: >9 Million Times;
Warranty: 18 Months;
|
Sensing Method: Electric;
Application: Access Control System;
Movement: Single Movement;
Type: Swing Gate;
Control Mode: Automatic;
Communication Interface: RS485;
Power Supply: 220VAC+15% 50Hz;
Work Environment: -25 - 70°C;
Working Sound: <60dB;
Maximum Opening Angle: +90°;
Driving Mode: Crank Connecting Rod Drive;
|
Sensing Method: Electric;
Application: Access Control System;
Movement: Single Movement;
Control Mode: Semi-Automatic;
Communication Interface: RS485;
Application1: Industry, Special Equipment, Traffic, Car/Motorcyc;
Application2: Boom Barrier Gate;
Usage: Door, Vehicle Detection;
Self-Turning Range: 20-2000uh;
Power Supply: 12-24VAC/DC 110-240VAC;
Operation Temp: -40 to +70;
Integral Fault Relay: Provide an Output in The Event of a Loop Fault Con;
Fast Response Times: Fast Response Times;
Relay Output: Presence Relay/Fault Relay;
ODM: Yes;
Ome: Yes;
|
Sensing Method: Electric;
Application: Access Control System;
Movement: Single Movement;
Control Mode: Semi-Automatic;
Communication Interface: Realy;
Application1: Industry, Special Equipment, Traffic, Car/Motorcyc;
Application2: Boom Barrier Gate;
Usage: Door, Vehicle Detection;
Self-Turning Range: 20-2000uh;
Power Supply: 12-24VAC/DC 110-240VAC;
Operation Temp: -40 to +70;
Integral Fault Relay: Provide an Output in The Event of a Loop Fault Con;
Fast Response Times: Fast Response Times;
Relay Output: Presence Relay/Fault Relay;
ODM: Yes;
Ome: Yes;
Sensitivity Adjustment: 16-Level;
Response Time: 10-90 Ms;
Operating Temperature: -40°C to +70°C;
|
Application: Access Control System;
Movement: Single Movement;
Control Mode: Semi-Automatic;
Application1: Industry, Special Equipment, Traffic, Car/Motorcyc;
Application2: Boom Barrier Gate;
Usage: Door, Vehicle Detection;
Self-Turning Range: 20-2000uh;
Power Supply: 12-24VAC/DC 110-240VAC;
Operation Temp: -40 to +70;
Integral Fault Relay: Provide an Output in The Event of a Loop Fault Con;
Fast Response Times: Fast Response Times;
Relay Output: Presence Relay/Fault Relay;
ODM: Yes;
Ome: Yes;
|