| Specification |
Application: Electronic, Instrument, Electricity Meter;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement, Electricity Meter;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Window Size: 80*120mm;
Input: 250-1000A;
Output: 1A/5A;
Accuracy: 0.5/1.0;
Frequency: 50-400Hz;
Construction: Screw;
Case: PBT;
Core: Silicon Steel;
Is_Customized: Yes;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Harvesting Energy;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement, Harvesting Energy;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Coil Structure: Toroidal & Split;
Material: Permalloy;
Cross-Sectional Area(mm²): 400;
Weight(G): 778.56;
Inductance(Uh)(1K 1V 25℃): 34.7;
Magnetic Circuit Length (mm): 235.5;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Harvesting Energy;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement, Supply Power;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Core: Permalloy;
Primary Input: 20A;
Output Power: 3W;
Lead Time: 7-15 Working Days;
Turns Ratio: 2000t;
Voltage: 5~550kv;
Accuracy: 0.2/0.5;
Continuous Current: 1250A;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Input Current: 5-6300A;
Secondary Output Current: 5A, 1A, 0.1A, 0.05A;
Rated Voltage: AC0.66kv=AC0.69kv;
Frequency: 50-60Hz;
Altitude: 3000m;
|