| Specification |
Accuracy: ± 5%;
Maximum Measurement Range: ≤3D;
Density Meter Type: Reflection Density Meter;
Viscometer Type: Rotary;
Density Meter Principle: Archimedes Buoyancy Method;
Test Density: Heavy;
Viscometer Reproducibility: ±0.2%;
Viscometer Rotor Number: 4;
Viscometer Rotor Speed: 6r/min;
Viscometer Rotor Specifications: 1 Size;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
Accuracy: ±5% (for Newtonian Liquids);
Maximum Measurement Range: 1 MPa•s-1×106MPa•s;
Viscometer Type: Rotary;
Density Meter Principle: Rotational Viscometer;
Test Density: Heavy;
Viscometer Rotor Number: 4;
Viscometer Rotor Speed: 750 Rpm, 75 Rpm, 7.5 Rpm;
R&D Capacity: OEM/ODM;
Measurement Range: 1 MPa•s-1×106MPa•s;
Measuring Accuracy: ±5% (for Newtonian Liquids);
Measuring Unit: Unit II and Unit III;
Rotating Speed: 750 Rpm, 75 Rpm, 7.5 Rpm;
Power Supply: AC 220 V±10%, 50 Hz;
Dimension: 170 mm×140 mm×440 mm;
Weight: 15 Kg;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
Accuracy: ±1%;
Maximum Measurement Range: 10 MPa•s-2000000 MPa•s;
Viscometer Type: Rotary;
Density Meter Principle: Rotational Viscometer;
Test Density: Heavy;
Viscometer Rotor Number: 4;
Viscometer Rotor Speed: 0.3;0.6;1.5;3;6;12;30;60rpm;8 Grades in Total;
R&D Capacity: OEM/ODM;
Measurement Range: 10 MPa•s-2000000 MPa•s;
Spindle: No.1-No.4, Four Spindles;
Rotation Speed: 0.3;0.6;1.5;3;6;12;30;60rpm;8 Grades in Total;
Measuring Accuracy: ±1% (F•s);
Power Supply: AC 220 V±10%, 50 Hz±10%;
Ambient Temperature: 5 ℃-35 ℃;
Relative Humidity: ≤80%;
Printing Output: Needle Printer;
Comunication Port: RS232 Port;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
Accuracy: ±1%;
Maximum Measurement Range: 10 MPa•s-100000 MPa•s;
Viscometer Type: Rotary;
Density Meter Principle: Rotational Viscometer;
Test Density: Heavy;
Viscometer Rotor Number: 4;
Viscometer Rotor Speed: 6 Rpm, 12 Rpm, 30 Rpm, and 60 Rpm;
R&D Capacity: OEM/ODM;
Measurement Range: 10 MPa•s-100000 MPa•s;
Spindle: No.1-No.4, Total Four Spindles;
Rotation Speed: 6 Rpm, 12 Rpm, 30 Rpm, and 60 Rpm;
Measuring Accuracy: ±1% (F•s);
Power Supply: AC 220 V±10%, 50 Hz±10%;
Ambient Temp.: 5 ℃-35 ℃;
Relative Humidity: ≤ 80%;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
Accuracy: ±1%;
Maximum Measurement Range: 100MPa•s-(2×105)MPa•s;
Viscometer Type: Rotary;
Density Meter Principle: Rotational Viscometer;
Test Density: Heavy;
Viscometer Rotor Number: 4;
Viscometer Rotor Speed: 5rpm, 10 Rpm, 20 Rpm, and 50 Rpm;
R&D Capacity: OEM/ODM;
Measurement Range: 100MPa•s-(2×105)MPa•s;
Spindle: No.21, 27, 28 and 29 Total 4 Pieces of Spindles;
Rotation Speed: 5rpm, 10 Rpm, 20 Rpm, and 50 Rpm;
Measurement Error: ±1% (F•s);
Temperature Control Range: 45 ℃-200 ℃;
Temperature Control Accuracy: ±0.1 ℃;
Sample Cylinder: 20 Ml;
Power Supply: AC 220V±10%, 50 Hz;
Ambient Temperature: 5 ℃-35 ℃;
Relative Humidity: ≤80%;
Printing Output: Needle Printer;
Comunication Port: RS232 Port;
|