| Specification |
After-sales Service: Quality Problems Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±0.6-1%;
Main Application: Nature Gas, Air, Biogas;
Size: DN25-DN200;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Turbine Flow Meter;
Measuring Media: Gas;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Output Type: RS485, Pulse and 4-20mA;
Connection Type: Flange;
Body Material: Aluminum Alloy;
Power Supply: 24VDC, 3.6VDC Battery;
|
After-sales Service: Good;
Warranty: 12 Months;
Accuracy: ≤±0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN10-DN500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Appliation: for Conductive Liquid (Conductivity>20);
Material: Carbon Steel, Stainless Steel;
Water Temperature: -25~180c;
Water Pressure: 0.6MPa~4MPa;
Standard: ISO9001;
Output: 4-20mA/Pulse/RS485/RS232;
|
After-sales Service: Good;
Warranty: 12 Months;
Accuracy: ≤±0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN10-DN500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Appliation: for Conductive Liquid (Conductivity>20);
Material: Carbon Steel, Stainless Steel;
Water Temperature: -25~180c;
Water Pressure: 0.6MPa~4MPa;
Standard: ISO9001;
Output: 4-20mA/Pulse/RS485/RS232;
|
After-sales Service: on Line;
Warranty: 12 Months;
Accuracy: 0.1-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: < DN5;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Mechanics;
Measurement Object: Open Channel;
Product Name: Coriolis Mass Flowmeter for CNG Dispenser with Ate;
Key Word: Mass Flow Meter;
Measurement Method: Directly Measure Mass Flow;
Measurement Accuracy Affected Factor: Only by Vibration;
Special Medium: Gases with Minimal Liquid Content;
Measure Parameters: Mass Flow, Temperature, Density, Volume Flow;
Installation Requirements: No Need to Consider Upstream and Downstream;
Measurable Medium: High-Viscosity , Liquids with Trace Solids;
|
After-sales Service: Maintain;
Warranty: 1year;
Accuracy: ±0.5%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas;
Size: DN15 (½") to DN1200 (48");
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Brand Name: Endress+Hauser;
Place of Origin: Switzerland;
Measurement Range: 5m;
Medium: Water;
Liquid Range: 5m or 8m;
Precision Accuracy: ±3 mm or 0.2%;
Connectivity: Flange;
Customized Support: OEM, ODM, Obm;
Resolution Ratio: 1mm;
Power Supply: 24VDC (Standard); 220VAC (Optional);
Flow Measurement Range: 0.1~10 M/S;
Ambient Temperature: -25~+60°c;
Temperature Effects: ±0.1% Fs/10K;
Power Supply Voltage: 24VDC;
Output Signal: 4-20mA+Hart;
|