| Specification |
Application: Industrial;
Warranty: 1 Year;
Detection Method: Spectroscopy;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Polychromator;
Customized: Customized;
Delivery Time: 14days;
|
After-sales Service: Lifelong;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Infrared;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Polychromator;
Customized: Customized;
Wavelength Range: 1000-1800 Nm;
Measurement Mode: Diffuse Reflectance;
Optical Brandwith: 10.95 ± 0.3 Nm @ 1395.5 Nm;
Signal to Noise Ratio: > 10000:1;
Sample Volume: 200ml;
Wavelength Repeatability: < 0.05 Nm;
|
After-sales Service: Online Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Customized: Non-Customized;
Model: Bk-UV1800PC;
Optical System: Single Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Bandwidth: 2nm;
Wavelength Accuracy: ± 0.5nm;
Wavelength Repeatability: ≤ 0.3nm;
Photometric Accuracy: ± 0.002A (0~0.5ABS);
Photometric Repeatability: 0.001ABS (0~0.5ABS), 0.002ABS (0.5~1.0ABS),;
Stray Light: ≤ 0.05% T @ 360nm; 220nm;
Stability: ± 0.001A / H @ 500nm;
|
After-sales Service: Online Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: /;
Dispersive Element: /;
Light Number: /;
Customized: Customized;
Inter-Channel Interference: 1.0%;
Sample Form: Solid;
Test Time: 100s;
Non Destructive: Xrf Test Will Not Destroy Your Gold Sample.;
Multi-Functional: Besides The Gold,Non Precious Metals, Can Also Be;
Long-Term Operating Stability: 0.1% (Au≥95%);
Measuring Range: Precious Metals Au, PT, AG in All Kinds of Ornamen;
|
After-sales Service: Free Spare Parts; Online Support;
Application: Laboratory Apparatus;
Warranty: 2 Years;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Atomic Absorption;
Light Number: Monochromator;
Customized: Customized;
Heating Steps: 9 Steps;
Temperature Range (Nominal Temperature): 20 Celsius~3000 Celsius;
Slope Heating Time: 0~999s;
Output: LCD;
Alarm System: Gas Pressure Alarm, Furnace Overheated Alarm;
|