| Specification |
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas;
Size: DN10~DN1600;
Type: Electromagnetic Flow Meter;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70℃;
Medium Temperature2: PTFE-20~120℃;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5KΩ, 4-20mA 0~750Ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|
After-sales Service: 24/7 Online After Sales Services;
Warranty: 12 Months After Delivery Date;
Accuracy: >±1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas;
Size: DN15-DN200;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Variable Area Flow Meter;
Measuring Media: Liquid and Gas;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Connection Type: Flange, Thread, Clamping;
Output: 4-20mA;
Explosion Proof: Exd II CT6;
IP: 67;
Range Down: 10:1;
Electrical Interface: M20×1.5 Special Can Be Customized;
Power Supply: 3.6V Lithium Battery, 24VDC;
Float Material: 304 or 316 L, PTFE or P.F.a;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Caliber: DN3 - 3000;
Signal Output Function: 4-20mA/Pulse;
Temperature of Medium: -20~+60deg C;
Communication Signal: RS485(Standard), Hart(Optional),GPRS/GSM (Optiona;
Nominal Pressure: 0.6-1.6MPa;
Power Supply: AC22V and DC24V;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Caliber: DN3 - 3000;
Signal Output Function: 4-20mA/Pulse;
Temperature of Medium: -20~+60deg C;
Communication Signal: RS485(Standard), Hart(Optional),GPRS/GSM (Optiona;
Nominal Pressure: 0.6-1.6MPa;
Power Supply: AC22V and DC24V;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Caliber: DN3 - 3000;
Signal Output Function: 4-20mA/Pulse;
Temperature of Medium: -20~+60deg C;
Communication Signal: RS485(Standard), Hart(Optional),GPRS/GSM (Optiona;
Nominal Pressure: 0.6-1.6MPa;
Power Supply: AC22V and DC24V;
|