| Specification |
After-sales Service: Free;
Warranty: 18 Month;
Display: Indicator;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Customized;
Product Name: MID 3 Phase Modbus Energy Meter;
Voltage: 3*230/400V;
Current: 0.25-5 ~30/32/40/45/50/80A;
Frequency: 50Hz;
Accuracy Class: Class B;
Impulse Constant: 1000imp/Kwh,1000imp/Kvarh;
Communication: IR,RS485 Modbus;
Standard: En50470-1/3;
Power Consumption: < 2W,<10va;
Starting Current: 0.004ib;
Temp. Range: -20~70 Degree;
Relative Humidity: 90%;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Installation: DIN-Rail Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: 333mv CT, Rogowski Coil;
Type: Power Meter;
Customized: Customized;
Input Type: External CT(333mv Only), External Rogowski Coil;
Programmable Digital Output: Alarm, 3 Tariff;
Power: 85~265V AC/DC;
Storage: 4 GB SD Card;
Poles Description: 3pH4w 3pH3w 1pH2w (L-N) 1pH2w(L-L) 1pH3w(L-L-N);
Device Application: Power Analysis, Tariff Meter;
Sampling Rate: 8K Samples Per Second;
Harmonic: 52th Max;
Data Acquisition Rate: 400ms;
Display Update Rate: 0.5s;
Transmission Mode: Modbus RTU, RS485 Port;
Primary Current Range: Adjustable From 0.1A to 9999A;
Voltage: 100V to 500V AC;
Frequency Range: 50/60Hz;
Display Screen: 2.0 Inch TFT Screen Display;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Installation: DIN-Rail Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: 333mv CT, Rogowski Coil;
Type: Power Meter;
Customized: Customized;
Input Type: External CT(333mv Only), External Rogowski Coil;
Programmable Digital Output: Alarm, 3 Tariff;
Power: 85~265V AC/DC;
Storage: 4 GB SD Card;
Poles Description: 3pH4w 3pH3w 1pH2w (L-N) 1pH2w(L-L) 1pH3w(L-L-N);
Device Application: Power Analysis, Tariff Meter;
Sampling Rate: 8K Samples Per Second;
Harmonic: 52th Max;
Data Acquisition Rate: 400ms;
Display Update Rate: 0.5s;
Transmission Mode: Modbus RTU, RS485 Port;
Primary Current Range: Adjustable From 0.1A to 9999A;
Voltage: 100V to 500V AC;
Frequency Range: 50/60Hz;
Display Screen: 2.0 Inch TFT Screen Display;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Installation: Panel Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: RJ45;
Measured Signal: 333mv CT, Rogowski Coil;
Type: Power Meter;
Customized: Customized;
Input Type: External CT(333mv Only), External Rogowski Coil;
Poles Description: 3p3w, 3p4w;
Frequency Range: 50/60Hz;
Application: Current,Voltage,Power,Energy and Harmonic Measurem;
Display Screen: 3.8 Inch LCD Segment Code Display Screen;
Current Sensor Type: 333mv CT, Rogowski Coil;
Advantage: 3 in 1 Current Sensor with RJ45 Port;
Primary Rated Current: 5A, 100A, 600A, 2500A, 6000A;
Secondary Rated Input: 333mv, 50mv/Ka@50Hz, 85mv/Ka@50Hz;
Recommended Sensor: STP CT, STP Rogowski Coils;
Voltage Range: 0~600VAC Phase to Phase Voltage;
Communication: Modbus RTU, RS485 Port;
Power Supply: 95~265VAC/110~260VDC, 45~60Hz;
Maximum Power Consumption: 3.5va;
Data Refresh Rate: 500ms;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Installation: Panel Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: RJ45;
Measured Signal: 333mv CT, Rogowski Coil;
Type: Power Meter;
Customized: Customized;
Input Type: External CT(333mv Only), External Rogowski Coil;
Poles Description: 3p3w, 3p4w;
Frequency Range: 50/60Hz;
Application: Current,Voltage,Power,Energy and Harmonic Measurem;
Display Screen: 3.8 Inch LCD Segment Code Display Screen;
Current Sensor Type: 333mv CT, Rogowski Coil;
Advantage: 3 in 1 Current Sensor with RJ45 Port;
Primary Rated Current: 5A, 100A, 600A, 2500A, 6000A;
Secondary Rated Input: 333mv, 50mv/Ka@50Hz, 85mv/Ka@50Hz;
Recommended Sensor: STP CT, STP Rogowski Coils;
Voltage Range: 0~600VAC Phase to Phase Voltage;
Communication: Modbus RTU, RS485 Port;
Power Supply: 95~265VAC/110~260VDC, 45~60Hz;
Maximum Power Consumption: 3.5va;
Data Refresh Rate: 500ms;
|