| Specification |
Range: 30m,70m,120m;
Measurement Accuracy: ±2mm,±5mm;
Kind: Liquid Level Transmitter;
Structure: Flange, Clamp, Thread;
Warranty: 1 Year;
Material: SS304;
Process Temperature: -40℃~200℃;
Processing Pressure: -1~2bar,-1~20bar;
Explosive-Proof Grade: Exiaiict6GB/Exdia(Ia Ga)Iict6/T2GB;
Level of Protection: IP67/IP68;
GHz: 76-81 GHz;
Signal Output: 4-20mA/Hart(Two Lines/Four Lines)RS485/Mod Bus;
|
Warranty: 1 Year;
Process Temperature: -40~300℃;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: Maintenance & Refund;
Range: up to 120m;
Measurement Accuracy: ±3mm;
Accuracy: 0.2%;
Kind: Radar;
Structure: All in One;
Warranty: 1 Year;
Material: SS304;
Process Temperature: -40 ~ +1000deg.C;
Connection Method: Threaded, Bracket, Flange, Sanitary Clamp;
Protection Rating: IP68;
Chip Technology: Silicon-Based (Current) / GaAs (Available Q2 2025);
Display: OLED with Multi-Language Support;
Beam Angle: 3°;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|