| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Current: 32A to 63A;
Keyword: RCCB;
Keyword2: Electric Circuit Breaker;
Keyword3: ELCB;
Keyword4: 10mA, 30mA, 100mA, 300mA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Imp: 6ka/10ka;
Max Current: 63A;
Tripping Curve: B/C;
Enclosure Box: with/Without;
Rated Current: 6A, 10A, 16A, 20A, 32A, 40A, 63A;;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Imp: 6ka/10ka;
Max Current: 63A;
Tripping Curve: B/C;
Enclosure Box: with/Without;
Rated Current: 6A, 10A, 16A, 20A, 32A, 40A, 63A;;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 2p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO;
Rated Voltage: 230/400V AC;
Inc: 6/10ka;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Recloser;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Product Name: Sf6 Vacuum Circuit Breaker;
Orign of Place: Zhejiang, China;
Related Voltage: 0-12V;
Rated Frequency: 50Hz;
Rated Current: up to 1000A;
OEM: Offered;
MOQ: 1PCS;
Mechanical Life: 10000 Times;
Net Weight: 140 Kg;
|