| Specification |
Type: Rogowski;
Output Signal Type: Digital Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.1%, 0.2%;
Application: Q8a2 Fpr Digital Multi-Meter;
IP Rating: IP67;
Customized: Customized;
|
Type: Electromagnetic;
Output Signal Type: Digital Output;
Production Process: SemiConductor Integrated;
Material: Stainless Steel;
Accuracy Grade: 1.0G;
IP Rating: IP20;
Customized: Customized;
Phase: Single;
Coil: Core-Type Transformer;
|
Type: Electromagnetic;
Output Signal Type: Digital Output;
Production Process: SemiConductor Integrated;
Material: Stainless Steel;
Accuracy Grade: 1.0G;
IP Rating: IP20;
Customized: Customized;
Phase: Single;
Coil: Core-Type Transformer;
|
Type: Amplifier/Integrator/Converter/Conditioner;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Compact Shield Aluminium Alloy Enclosure;
Accuracy Grade: ±1%;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Outer Casing: Compact Shield Aluminium Alloy Enclosure;
Rated Output: 1V AC Peak,Maximum Output(Overload) 12V AC Peak;
Rated Ratio: 1ka/1V, 10ka/1V, 50ka/1V...;
Frequency: 100kHz to 1MHz;
Power Supply: 4-12V DC (Included 85-265AC to 12V DC Adaptor);
Read Accuracy: 2% Typical at 10% to 1000% of Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.5% of Reading(10% to 1000% of Range);
Response Time: ≤1us;
Power Consumption: 300MW;
Terminal(Lock Type): Input:Locked with Coil Signal Cable, Output:BNC;
Current Sensor: Rogowski Coil H-Fct,H-Mrc,H-Zrc;
High Frequency Current Signal: 1/5μs,8/20μs,10/350μs;
Direct Connection: Oscilloscope;
Lightning Current Measurement: up to 500ka;
|
Type: Amplifier/Integrator/Converter/Conditioner;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Compact Shield Aluminium Alloy Enclosure;
Accuracy Grade: ±1%;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Outer Casing: Compact Shield Aluminium Alloy Enclosure;
Rated Output: 1V AC Peak,Maximum Output(Overload) 12V AC Peak;
Rated Ratio: 1ka/1V, 10ka/1V, 50ka/1V...;
Frequency: 100kHz to 1MHz;
Power Supply: 4-12V DC (Included 85-265AC to 12V DC Adaptor);
Read Accuracy: 2% Typical at 10% to 1000% of Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.5% of Reading(10% to 1000% of Range);
Response Time: ≤1us;
Power Consumption: 300MW;
Terminal(Lock Type): Input:Locked with Coil Signal Cable, Output:BNC;
Current Sensor: Rogowski Coil H-Fct,H-Mrc,H-Zrc;
High Frequency Current Signal: 1/5μs,8/20μs,10/350μs;
Direct Connection: Oscilloscope;
Lightning Current Measurement: up to 500ka;
|