| Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Common Insulating Materials;
Installation: Clamp;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Current: 0~100A;
Second Current: 0~100mA;
Ratio: 1000:1 or Customized;
Accuracy: 0.1%;
Weight: 320g;
Types: Clamp on Current Transformer;
Output Signal: 0-100mA or 0-100mv;
Working Temperature: -20-+55deg;
Dimension: 52.5mm X 136.5mm X 28 mm;
Output Cable: 2.5m;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy Class: 0.05, 0.1, 0.2;
Application Range: Energy Meter;
Max Current: 5A-300A;
Current Transformer Ratio: 1:1000, 1:2000, 1:2500;
DC Immunity: DC Immunity;
Material: Nano Crystalline, Ferrite Core;
Self Heating Testing: Pass Self Heating Testing;
DC Tolerance: Good DC Tolerance;
Standard: IEC62052-31;
Rosh: Rosh Compliant;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: as Specification;
Insulating Medium: as Specification;
Installation: as Specification;
Magnetic Circuit Structure: as Specification;
Voltage Transformation Principle: as Specification;
Product Name: Current Transformer;
Diameter of Inner Hole: 80;
Accuracy Class: 10p10;
|