| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Standard;
Installation: Standard;
Structure: Standard;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Product Name: Push to Reset Circuit Breaker;
Rated Current: 2A-15A;
Rated Voltage: 12V-250VAC;
Reset: Manual, Push to Reset;
Dielectric Strength Resettable: 1,500VAC1 Minute;
Interrupting Capacity: 125/250VAC X 1,000A;
Typical Life: 1,000 Operations at 200% Overload;
Insulation Resistance: >100m Ohms;
Pole: Single Pole;
Color: Grey;
Terminal: 6.35mm;
Mounting Type: Snap-in Mount;
Application: UPS Power Supply, Instruments, Small Generators;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Structure: Load Break Switch;
Poles Number: 3;
Type: Circuit Breaker;
Grounding: Un Grounded;
Run: Plug-in;
Common Model: Fln;
Rated Voltage: 12kv;
Mechanical Life: 10000 Times;
New Weight: 210kgs;
Switching Mode: Double-Throw Type;
Rated Frequency: 50Hz;
OEM: Avaliable;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-3;
Rated curret (In): 63A, 80A,100A,125A;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated impulse withstand voltage (Uimp): 6kA;
Electrical life: 4000;
Mechanical life: 20000;
Protection degree: IP20;
Rated making and breaking capacity: 3le, 1.05ue,cosΦ=0.65;
Using the categories: AC-22A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-2, GB14048-2;
Rated curret (In): 80A,100A,125A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Main Switch;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-3;
Rated curret (In): 63A,80A,100A,125A;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Rated impulse withstand voltage (Uimp): 6kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
Using the categories: AC-22A;
Rated making and breaking capacity: 3le, 1.05ue,cosΦ=0.65;
|