| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Installation: Surface Mount;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
for: Waterproof;
Operating Temperature: -32c to 82c (-25f to 180f);
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN RAIL;
Structure: MCB;
Poles Number: 1P 2P 3P 4P;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Standard: IEC60898-1;
Protection Function: Short Circuit Protection, Overload Protection;
Rated insulation voltage: 250Vdc, 500Vdc, 750Vdc for 3P, 1000Vdc for 4P;
Rated ultimate breaking capacity: 15000A;
Rated service breaking capacity: 15000A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 8kv;
in: 400/500/630A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
ICU: 50ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Frequency: 50Hz;
Ue: 400/415V;
Ui: 500V;
Uimp: 8kv;
in: 400/500/630A;
Flashover Distance: <50mm;
Working Temperature: -5 Degree to +40 Degree;
Standard: IEC60947, GB/T 14048;
ICU: 65ka;
|