| Specification |
Customized: Customized;
Portable: Portable;
Type: Electrochemical Gas Analyzer;
Material: Aluminum;
Gas Detection: Toxic Gases, O2,CO2, Ex, Tvoc, etc;
Detection Principle: Ec,Catalytic,IR,Tcd,Semi,Zro2,Pid,Tdlas(Selectable;
Typical Accuracy: ≤ 3% F.S. (Higher Accuracy Customizable);
Response Time: T90≤ 30 Seconds;
Operating Environment: Ambient Temp: -20℃ ~ +55℃ (Typical), -40℃ ~ +70℃ (;
Signal Output: RS485, 4-20mA, Optional 0-5V/10V, etc.;
Operation & Sampling Mode: Diffusion, Pump Suction, Flow-Through Optional;
|
After-sales Service: 24 Hours Online Service;
Warranty: 1 Year;
Brand: Kelisaike;
Customized: Customized;
Portable: Non Portable;
Gas: Customized;
Type: Non-Dispersive Infrared Analysis;
Sampling: Diffusion;
Power: 24V DC or 220V AC;
Service Life: 2 Years;
Signal Output: 4-20mA;
Operating Temperature: -20℃ ~ +50℃;
Relative Humidity: 15%-90%Rh(Non-Condensing);
Display: 4-Digit LED;
Pressure: 86-106kpa;
Alarm Mode: Acousto Optic Alarm;
Transmission Distance: Max.1000m;
Wiring: 3-Core Shield Cable, 3×1.0mm;
Enclosure: Aluminum Alloy and Stainless Steel;
Explosion-Proof Grade: Exd Iic T6;
|
After-sales Service: 24 Hours Online Service;
Warranty: 1 Year;
Brand: Kelisaike;
Customized: Customized;
Portable: Non Portable;
Gas: Customized;
Type: Non-Dispersive Infrared Analysis;
Sampling: Diffusion;
Power: 24V DC or 220V AC;
Service Life: 2 Years;
Signal Output: 4-20mA;
Operating Temperature: -20℃ ~ +50℃;
Relative Humidity: 15%-90%Rh(Non-Condensing);
Display: 4-Digit LED;
Pressure: 86-106kpa;
Alarm Mode: Acousto Optic Alarm;
Transmission Distance: Max.1000m;
Wiring: 3-Core Shield Cable, 3×1.0mm;
Enclosure: Aluminum Alloy and Stainless Steel;
Explosion-Proof Grade: Exd Iic T6;
|
After-sales Service: Online Support;
Warranty: 1 Year;
Brand: Renke;
Customized: Customized;
Portable: Non Portable;
Gas: O2;
Type: Electrochemical Gas Analyzer;
Power Supply: 10~30V DC;
Output Signal: RS485/4-20mA/0-5V/0-10V;
Alarm Type: Sound+Light Alarm;
Measure Range: 0-30%Vol;
Accuracy: ±2%Fs;
Resolution: 0.1 %Vol;
Response Time: ≤10s;
Display: LCD Screen;
Zero Drift: ±0.3%Vol;
|
Warranty: 1 Year;
Brand: Veinasa;
Customized: Customized;
Portable: Non Portable;
Gas: Tvoc;
Measuring Range: 0~60000ppb;
Relative Error: ±8%Fs±125ppb;
Minimum Detection Particle: 1ppb;
Power Supply: (Default) DC 10-30V;
The Maximum Power Consumption: Less Than 0.8W;
Working Temperature: - 10 ℃ - 55 ℃;
Working Humidity: 0 ~ 95% Rh, Non Condensing;
Signal Output: RS485 Output (Standard Modbus RTU Protocol);
Material: ABS;
Installation Method: Bracket Installation;
|