| Specification |
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Current: 50-800A;
Relay Current: 10p10 10p15 10p20;
Operative Norm: IEC61869-1/2;
Ambient Temperature: -5℃-+40℃;
Rated Frequency: 50Hz 60Hz;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Current: 50-800A;
Relay Current: 10p10 10p15 10p20;
Operative Norm: IEC61869-1/2;
Ambient Temperature: -5℃-+40℃;
Rated Frequency: 50Hz 60Hz;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 10kv;
Rated Frequency: 50Hz/60Hz;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Current: 50-800A;
Relay Current: 10p10 10p15 10p20;
Operative Norm: IEC61869-1/2;
Ambient Temperature: -5℃-+40℃;
Rated Frequency: 50Hz 60Hz;
|