| Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: PCB Mounting;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
N.W: 7.04G;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Input Current: 5-6300A;
Secondary Output Current: 5A, 1A, 0.1A, 0.05A;
Rated Voltage: AC0.66kv=AC0.69kv;
Frequency: 50-60Hz;
Altitude: 3000m;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Type1: Current Transformer;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Voltage Current Transformer;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Voltage, Power and Energy Monitoring D;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy: 0.2 0.5 Voltage Current Transformer;
Isolation Voltage: 2500 Vrms for 1 Minute;
Dielectric Resistanc: 1000 M Ohms @ 500 VDC;
Rated Load Resistance: 100K Ohms;
Operating Temperature: -25 to +55c, -40 to +85c Optional;
Frequency: 50 to 400 Hz;
Accuracy Class: as Defined in IEC 60044-2 Part 2 Volta;
Input Voltage: 57.7V-600V;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Relay Prodtion HVAC;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy Class: 0.5 1.0s: Ratio : 3000:1;
Protection: 5 Times Protection, 10 Times Protecti;
Split Core Current Transformer: 0.333-3.53V Rated Secondary Output;
Application 1: Current, Power, Energy, Monitoring Devices;
Application 2: Power Factor Correction Devices.;
Rated Load: 1, 2.5, 5.0, 10, 30va;
Highest Voltage for Equipment Um (RMS): 720 VAC;
Frequency Range: 50/60Hz;
Rated Power-Frequency Withstand Voltage;: 3, 000 VAC;
Output Split Core CT: Standard:IEC 60044-1;
Name: Current Probe;
Product1: Split CT Transformer;
Product2: ETL Current Probe Transformer;
Product 3: 600A 100A 5A Split Core CT;
|