| Specification |
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Mixture;
Accuracy Grade: 0.5G;
Application: Solar Combiner Box, Photovoltaic (PV) Current Appl;
IP Rating: IP44;
Customized: Customized;
Rated Input: 15/20/25 /30A;
Measuring Range: 0~+-30A;
Supply Voltage: DC +3.3V~5.0 V;
Output Voltage: 1.650+-1.250V;
Offset Voltage: @IP=0, T=25c < +-20 Mv;
Power Consumption: 10mA;
Primary Through-Hole: D 8.5+-0.15mm;
Plastic Material: PBT G30/G15, UL94-V0;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated Current;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Outer Casing: Plastic Enclosure;
Rated Current: 100A-6000A;
Rated Output: 333mv, 3V AC RMS or 4V DC(True-RMS);
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 70MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 5V Only for Output 333mv; or 6-12V or 24VDC;
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Output on 0A (Zero Drift): ≤5mv;
Terminal: Terminal(3.81 Interval), 4pin, Rj12 Crystal Head;
Current Sensor: Trc, Mrc, Nrc, Y-Fct;
Applicable Scenario: Connect to Power Meter or PLC;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
IP Rating: IP20;
Customized: Customized;
Outer Casing: Plastic Enclosure;
Rated Current: 100A-6000A;
Rated Output: 333mv, 3V AC RMS or 4V DC(True-RMS);
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 70MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 5V Only for Output 333mv; or 6-12V or 24VDC;
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Output on 0A (Zero Drift): ≤5mv;
Terminal: Terminal(3.81 Interval), 4pin, Rj12 Crystal Head;
Current Sensor: Trc, Mrc, Nrc, Y-Fct;
Applicable Scenario: Connect to Power Meter or PLC;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
IP Rating: IP20;
Customized: Customized;
Outer Casing: Plastic Enclosure;
Rated Current: 100A-6000A;
Rated Output: 333mv, 3V AC RMS or 4V DC(True-RMS);
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 70MW;
Bandwidth: 10Hz to 10kHz;
Power Supply: 5V Only for Output 333mv; or 6-12V or 24VDC;
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Output on 0A (Zero Drift): ≤5mv;
Terminal: Terminal(3.81 Interval), 4pin, Rj12 Crystal Head;
Current Sensor: Trc, Mrc, Nrc, Y-Fct;
Applicable Scenario: Connect to Power Meter or PLC;
|
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: ±1% of Ipn;
Application: Battery management;
Customized: Customized;
Supply Voltage: 3.3V;
Product: Current Sensor;
Accuracy: ±2.5;
Linearity: ±0.5;
|