| Specification |
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.7g;
Application: UPS & SMPS Current Sensing;
IP Rating: IP44;
Customized: Customized;
Rated Input: 05/10/15/25A;
Measuring Range: 0~+-80A;
Supply Voltage: DC +5.0V;
Output Voltage: 2.500+-0.625V;
Offset Voltage: @IP=0, T=25°C < +-25mv;
Power Consumption: 10mA;
Installation: PCB Mounting;
Plastic Material: PBT G30/G15, UL94-V0;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.5G;
Application: All Electronic, Electrical, Electric Related Cases;
IP Rating: IP65;
Customized: Customized;
Window Size: 24,36,50,100mm;
Reference Rated Current: 300A, 600A, 1000A;
Weight: Approx 80-100g;
Terminal: Cold Pressed Terminal, BNC...;
Coil Resistance: From 100-300Ω;
Current Range(RMS): 0.5-100ka AC;
Ratio: Calibrated 50mv/Ka@50Hz; Uncalibrated 60mv/Ka@50h;
Read Accuracy: Calibrated <0.5% (Central Position, 25℃);
Temperature Drift: Uncalibrated 200ppm/℃;
Position Error: ±1% Maximum;
Output on 0A(Zero Drift): ≤1mv;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading;
Bandwidth: 1Hz to 100kHz (-3dB);
Operating Temperature: -30℃ to 80℃;
|
Type: Rogowski;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.5G;
Application: All Electronic, Electrical, Electric Related Cases;
IP Rating: IP65;
Customized: Customized;
Window Size: 24,36,50,100mm;
Reference Rated Current: 300A, 600A, 1000A;
Weight: Approx 80-100g;
Terminal: Cold Pressed Terminal, BNC...;
Coil Resistance: From 100-300Ω;
Current Range(RMS): 0.5-100ka AC;
Ratio: Calibrated 50mv/Ka@50Hz; Uncalibrated 60mv/Ka@50h;
Read Accuracy: Calibrated <0.5% (Central Position, 25℃);
Temperature Drift: Uncalibrated 200ppm/℃;
Position Error: ±1% Maximum;
Output on 0A(Zero Drift): ≤1mv;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading;
Bandwidth: 1Hz to 100kHz (-3dB);
Operating Temperature: -30℃ to 80℃;
|
Type: Electromagnetic;
Output Signal Type: Digital Output;
Production Process: Injection;
Material: Plastic;
Accuracy Grade: 0.2G;
Application: Switching Power Supply;
IP Rating: IP22;
Customized: Customized;
Name: Outdoor Current Transformer;
Class: 0.5,0.5s,0.2;
Rated Primary Voltage: 0;
Rated Secondary Voltage: 0;
|
Type: Electromagnetic;
Output Signal Type: Digital Output;
Production Process: Integration;
Material: Plastic;
Application: Residual Current Detection;
Customized: Customized;
Product Name: 6mA DC Leakage Sensor Residual Current Monitor;
Measurement Current Range: DC Current:2~15mA ; AC Current:3~100mA;
Three-Ways Output: DC Alarm, AC Alarm, AC/DC Alarm;
Function: Current Value Readable and Settable;
Theory: Current Sensor;
Installation: Cable/Horizontal Type;
Application Scence: EV Charger, Solar PV System, DC Panel;
Appearance: Plastic Casing, SIP Encapsulation;
|