| Specification |
After-sales Service: Online Training, Reply Customer's Question in 12h;
Warranty: Tweleve Months;
Reference Standards: IEC 60112, ASTM D 3638-12, UL746A;
Application Field: Electrical Industry;
Function: Test Proof&Comparative Tracking Indices;
Test Object: Solid Insulating Materials;
Description: Material Comparative Tracking Indices Tester;
Features: IEC60112 Comparative Tracking Indices Tester;
Dimension: 630mm(W) * 390mm(D) * 750mm(H);
Electrode Material: Electrode Tip - Platinum Metal (Platinum);
Electrode Pressure: 1.0n;
Electrode Distance: 4.0mm;
Power Supply: 230 Volts Nominal 10 AMPS;
Delivery Lead Time: 25 Days;
Trade Term: Fob, CIF, DDU, EXW;
Shipping Method: by Air or Express;
Customized Service: OEM;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
R&D Capacity: OEM/ODM;
Power Supply: AC(220±10%)V, 50Hz;
Heating Tube Power: ≤1000W;
Measuring Range of Oxygen Bomb Pressure: (0-1600)Kpa;
Accuracy: ±2%;
Temperature Control Point of Metal Bath: 100.0℃±0.5℃;
Thermometer: Mercury-in Glass Thermometer;
Ambient Temperature: ≤40℃;
Relative Humidity: ≤85%;
Without Test Barrel: 470mm×380mm×320mm;
with Test Barrel: 470mm×380mm×600mm;
Net Weight: 25kg;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
R&D Capacity: OEM/ODM;
Test Method: Pulsed Ultraviolet Fluorescence;
Measurable Sample Status: Liquid, Gas, Solid;
Measuring Range: 0.1mg/L -10000mg/L (Liquid);
Lower Detection Limit: 0.05mg/L;
Repeatability Error: X≤0.5mg/L;±0.1mg/L;
Range: Room Temperature~1200 ℃;
Accuracy: 0.5% ± 1 ℃;
High Voltage Range: DC 0V - 900V;
Working Voltage: AC 220V±22V,50Hz±1Hz;
Total Power Consumption: ≤3000W;
Dimension: 660×500×400mm,Computer Is Not Included;
Net Weight: 40kg.(Computer Is Not Included);
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
R&D Capacity: OEM/ODM;
Measurement Range: 0.1mg/Kg-10000mg/Kg-%(S)/(N);
Lower Detection Limit: 0.05mg/Kg(S),0.1mg/Kg(N);
Measurable Sample: Solid, Liquid, Gas;
Pmt High Voltage Range: DC400V-900V;
Standard Curve Correlation Coefficient: ≥0.999;
Temperature Control Range and Accuracy: Rt-1300℃,±1℃;
|
After-sales Service: Supply Free Part for Quality Problem in Warranty;
Warranty: 1year;
R&D Capacity: OEM/ODM;
Power Supply: AC(220±10%)V, 50Hz;
Heater for Distillation Flask: 1300W;
Heater for Receiver: 350W;
Heating Furnace of Distillation Flask: (0-1300)W, Continuously Adjustable;
Temperature Sensor of Air Bath: PT100,Rtd;
Temperature Control Mode: Digital Temperature Controller;
Temperature Control Precision: Set Temp.±1℃;
Capacity of Buffer Vessel: 1000ml;
Max. Residual Pressure: 2mmhg;
Digital Pressure Gauge: (0-200)Mmhg;
Illumination Light in The Air Bath: Energy Saving Lamp;
Ambient Temp.: (15-35)℃;
Rh: < 85%;
Dimension: 600mm×250mm×650mm;
|