| Specification |
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: ≤1%;
Application: electronic measurement of curre;
Customized: Customized;
Supply Voltage: +24V(±5%);
Product: Current Sensor;
|
Type: Integrator/Amplifier/Converter/Transducer/Sensor;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5% Typical at 1%(≥10A) to 200% of Rated;
Application: Leakage Current/Small Current;
IP Rating: IP20;
Customized: Customized;
Rated Input: 5A/50A(Switchable);
Rated Output: 3V AC RMS;
Current Sensor: Fixed with Rogowski Coil Src-50;
Output Terminal: 0.5 Meter BNC Male Terminal;
Output Ripple Factor: 1%;
Response Time: ≤1us;
Power Consumption: 0.2va;
Bandwidth: 10Hz to 10kHz;
Power Supply: DC 5V/2A Adaptor or 1.5V Battery;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Output on 0A (Zero Drift): ≤1mv;
Temperature Drift: 200ppm/℃;
Advantage: Mini Handheld Low Power Consumption;
|
Type: Integrator/Amplifier/Converter/Transducer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP68;
Customized: Customized;
Outer Casing: Waterproof Plastic Enclosure;
Rated Output: 4-20mA DC or 333mv;
Power Consumption: 100MW;
Bandwidth: 30Hz to 1kHz;
Power Supply: 12V or 24V DC;
Rated Input: 100A-6000A;
Output Wire: 0.5 Meter 4PCS Wires;
Response Time: Default 100ms(Adjustable);
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Rogowski Coil Y-Fct, Trc;
Applicable Scenario: Combine with Power Meter or PLC;
|
Type: Integrator/Amplifier/Converter/Transducer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP68;
Customized: Customized;
Outer Casing: Waterproof Plastic Enclosure;
Rated Output: 4-20mA DC or 333mv;
Power Consumption: 100MW;
Bandwidth: 30Hz to 1kHz;
Power Supply: 12V or 24V DC;
Rated Input: 100A-6000A;
Output Wire: 0.5 Meter 4PCS Wires;
Response Time: Default 100ms(Adjustable);
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Rogowski Coil Y-Fct, Trc;
Applicable Scenario: Combine with Power Meter or PLC;
|
Type: Integrator/Amplifier/Converter/Transducer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 1% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP68;
Customized: Customized;
Outer Casing: Waterproof Plastic Enclosure;
Rated Output: 4-20mA DC or 333mv;
Power Consumption: 100MW;
Bandwidth: 30Hz to 1kHz;
Power Supply: 12V or 24V DC;
Rated Input: 100A-6000A;
Output Wire: 0.5 Meter 4PCS Wires;
Response Time: Default 100ms(Adjustable);
Read Accuracy: 1% Typical at 1%(≥10A) to 200% of Rated;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Rogowski Coil Y-Fct, Trc;
Applicable Scenario: Combine with Power Meter or PLC;
|