| Specification |
After-sales Service: Support 1 Year Warranty;
Warranty: 1 Year;
Accuracy: ±0.1% of Span;
Main Application: Water;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Product Name: Emerson Rosemount RM8600d Utility Vortex Flowmeter;
Measured Variables: Vortex Shedding (Liquid, Gas, Steam);
Place of Origin: China;
Repeatability: ±0.25% of Reading;
Output Signal: 4–20 Ma (Hart® 7);
Power Supply: 10.5–42 V DC;
Process Connections: Flanged (ANSI/DIN/JIS), Threaded (NPT/Bsp), Sanita;
Materials: 316L Stainless Steel, Hastelloy C-22, Alloy C-276;
Output Signals: 4–20 Ma (Isolated), Hart® 7, Foundation;
Shock Resistance: 50g (11 Ms Half-Sine);
Operating Temperature: -40°c to +150°c (-40°f to +302°f);
Response Time: <1 Second;
EMC Immunity: 30 V/M (80 MHz–1 GHz);
Sensor Tube Design: Straight or Curved Coriolis Tubes (No Moving Parts;
Vibration Resistance: 2g RMS (10–2000 Hz);
|
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas;
Size: DN10~DN1600;
Type: Electromagnetic Flow Meter;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70℃;
Medium Temperature2: PTFE-20~120℃;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5KΩ, 4-20mA 0~750Ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas;
Size: DN10~DN1600;
Type: Electromagnetic Flow Meter;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70℃;
Medium Temperature2: PTFE-20~120℃;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5KΩ, 4-20mA 0~750Ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas;
Size: DN10~DN1600;
Type: Electromagnetic Flow Meter;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70℃;
Medium Temperature2: PTFE-20~120℃;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5KΩ, 4-20mA 0~750Ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|
After-sales Service: Online Technical Service;
Warranty: 1 Year;
Accuracy: ±0.01m/S, ±5mm;
Main Application: Water, Wastewater;
Size: < DN5;
Sensor: Plug-in;
Application: Environmental Protection;
Type: Radar Flowmeter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Measuring Range: 0.1-20;
Resolution: 0.01;
Antenna Angle: 12;
Flow Direction Recognition: Bidirectional automatic;
|