| Specification |
Warranty: Min. 2 Years;
Display: LCD;
Installation: CT Connected;
Usage: Power Quality Monitor;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Type: Energy Meter;
Customized: Non-Customized;
Allow Customized Logo: Yes (MOQ > 1000);
Power Supply (Standard): 95-250VAC/VDC ± 10%, (Optional 20-60VDC);
Input Voltage: 400VLN/690VLL;
Power Supply (Optional): Optional: 20-60VDC;
Rated Current: 5A/1A;
Measuring Energy: 0~99999999999.999kWh;
Accuracy: IEC 62053-22 Class 0.2S;
Frequency: 50/60 Hz;
Communication: Two Ethernet Ports, 1x RS-485 Port;
|
After-sales Service: Online/Video/Telephone Guidence;
Warranty: 24 Months;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Input Frequency Range: 45~65Hz;
Baud Rate: 2400 BPS to 38400 BPS, Configurable;
Measurement Accuracy: Current and Voltage: Class 0.2;
Communications: RS485 Interface, Modbus-RTU Protocol;
Input Voltage: 100V or 400VAC, with a Tolerance of ±25%;
Input Current: 5A, with a 20% Tolerance for Overcurrent;
Power Consumption: <2.5W;
Operating Temperature: -20°C to +75°C;;
Storage Temperature: -40°C to +85°C;;
Relative Humidity: 5% to 95% Non-Condensing.;
|
After-sales Service: Online/Video/Telephone Guidence;
Warranty: 24 Months;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Input Frequency Range: 45~65Hz;
Baud Rate: 2400 BPS to 38400 BPS, Configurable;
Measurement Accuracy: Current and Voltage: Class 0.2;
Communications: RS485 Interface, Modbus-RTU Protocol;
Input Voltage: 100V or 400VAC, with a Tolerance of ±25%;
Input Current: 5A, with a 20% Tolerance for Overcurrent;
Power Consumption: <2.5W;
Operating Temperature: -20°C to +75°C;;
Storage Temperature: -40°C to +85°C;;
Relative Humidity: 5% to 95% Non-Condensing.;
|
After-sales Service: 2 Years;
Warranty: 2 Years;
Display: Digital;
Installation: on Rail 35mm;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: None;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Specification1: 3 Phase 3 Wires and 3 Phase 4;
Reference Voltage: 3*100V 3*380V 3*57.7/100V 3*220/380V;
Input Current: 3*1(6)a 3*10(80)a;
Frequency: 45-65Hz;
Energy Pulse Output: 1 Active Photocoupler Output;
Interface and Communication Protocol: RS485 Modbus RTU;
Range of Communication Address: Modbus RTU:1~ 247;
Baud Rate: 1200BPS~19200BPS;
|
After-sales Service: Online/Video/Telephone Guidence;
Warranty: 24 Months;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Input Frequency: 45~65Hz;
Baud Rate: 2400 BPS to 38400 BPS, Configurable;
Measurement Accuracy: Current and Voltage: Class 0.2;
Communications: RS485 Interface, Modbus-RTU Protocol;
Power Consumption: <2.5W;
Input Voltage: 100V or 400VAC, with a Tolerance of ±25%;
Input Current: 5A, with a 20% Tolerance for Overcurrent;
Operating Temperature: -20°C to +75°C;;
Storage Temperature: -40°C to +85°C;;
Relative Humidity: 5% to 95% Non-Condensing.;
|