| Specification |
Type: Strength Testing Machine;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Electrical;
Display: LCD;
Control: Computer Control;
Power Source: AC220V;
Testing Method: Low Pressure Pulse Method, Impulse Lightning Flow;
Frequency: 6.25MHz,12.5MHz,25MHz,50MHz,100MHz;
Output Voltage: 0~-35kv;
Discharge Engergy: ≤1225j(2450j);
Usage: Network Cable Tester;
Component: Host,Power Supply,Tracing and Locator;
Measurement Distance: Less Than 60km   ;
Operating Model : Touch Pen and Mouse Operation;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extend;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: Depends;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Test Sample: Cable, Transformer, Switchgear, etc;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Contact Resistance Tester;
Power Source: AC220V;
Power of The Whole Machinepower: 600W;
Maximum Storage Records: 200;
Product Name: Circuit Breaker Contact Resistance Test;
.Measuring Range: 0 ~ 2999.9μω;
Test Current: DC 50A, 100A, 150A, 200A, Fixed Output.;
Accuracy: ±(0.5% Rd+2D);
Continuous Working Time: 5s~599s;
Communication Mode: USB;
Power Supply: AC220V±10% 50Hz;
Power of The Whole Machine: 1200W;
Maximum Storage Record: 200;
Standard: IEC;
Model Name: Loop Contact Tester;
Display Screen: Lcb;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extend;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: Depends;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Test Sample: Cable, Transformer, Switchgear, etc;
|
After-sales Service: Support;
Warranty: 1 Year;
Type: Earth Resistance Tester;
Weight: 18kg;
Power Source: AC180 to 270V, 50/60Hz;
Maximum Output Voltage: 450V;
Test Current Waveform: Sine Wave;
Measurement Range: 0~5000 Ω;
Resolution: 0.001m Ω;
Measurement Error: ± (Reading 2% + 0.005 Ω);
Test Current Frequency 1: Single Frequency: 40-70Hz;
Test Current Frequency 2: 50±0.1Hz to 50±10.0Hz;
Output Current: 5A or External Power Supply 30A;
Output Voltage: 400V or External Power Supply: 1000V;
|