| Specification |
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Transformer Test Bench;
Accuracy Grade: 0.5;
Display: LED;
Control: Manual Control;
Power Source: AC220V;
Function 1: Testing Turn Ratio;
Usage: Auto Testing Machine;
Function2: DC Resistance Test;
Function3: Power Frequency Withstand Voltage Test;
Function4: Induction Withstand Voltage Test;
Function5: 10kv No-Load Test;
Function6: 35kv No- Load Test;
Air Relative Humidity: <85%;
Transformer Ratio: 1--10000;
Max Test Current: 10A;
Product Name: Transformer Test Bench;
Model No: Hm5050;
Standard: IEC,GB;
Calibration Report: Factory Calibration Report or The Third Party Issu;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extend;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: Depends;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Test Sample: Cable, Transformer, Switchgear, etc;
|
After-sales Service: Life Long Support;
Warranty: 1 Year or Extended;
Type: DC Hipot Tester;
Display: Digital;
Control: Manual Control;
Power Source: AC220V;
Usage: DC High Voltage Tester;
Output Type: DC;
Output Voltage: 60-300kv;
Output Current: 2\3\5\10mA;
Over Voltage Rectify Accuracy: <=1.0%;
Ripple Factor: <=0.5%;
Altitude: Below 2500m;
Product Name: DC Hipot Tester;
Ripple: ≤0.5%;
Voltage Precision: 1% ±1 Word;
Standard: IEC;
Work Power: AC 220V±10%;50Hz;
0.75 Switch Over Accuracy: ≤0.5%;
Test Sample: Cable, Arrester, Transformer;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extend;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: Depends;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Test Sample: Cable, Transformer, Switchgear, etc;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Type: Cable Fault Locator;
Weight: 2.0 Kg Including Battery;
Power Source: Battery /Charging Battery;
Outer Shield Fault: 0 Ohm - 5meg Ohm;
Conduct Loop Resistance: 0-2K Ohm;
Battery Working Time: 24h/35h(Charging);
Battery Power Test: Auto;
Frequency: 50/60Hz;
Standard: IEC;
|