| Specification |
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extend;
Type: Transformer Tester;
Display: Digital;
Control: Computer Control;
Power Source: AC220V;
Test Range: (-100dB) - (+20dB);
Frequency Accuracy: <0.01%;
Scan Mode 1: Linear Scanning Distribution;
Scan Mode 2: Segment Frequency Scanning Measurement Distributio;
Frequency Scanning Measurement Range: (0.5kHz) - (1MHz);
Scanning Frequency Accuracy: 0.01%;
Amplitude Measurement Accuracy: 0.1dB;
Amplitude Measurement Range: (-120dB) to (+20 dB);
Ignal Input Impedance: 1mΩ;
Ignal Output Impedance: 50Ω;
Nw: 13kgs;
Standard: IEC;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Impedance Voltage: <12%;
Surface Temperature-Raising: < 55°c;
No-Load Current: < 4%;
Continuous Working Time: <=60 Mins;
Product Name: AC DC Hipot Tester;
Standard: IEC;
Power: Electric;
|
After-sales Service: Life Long Support;
Warranty: 1 Year;
Impedance Voltage: <12%;
Surface Temperature-Raising: < 55°C;
No-Load Current: < 4%;
Continuous Working Time: <=60 Mins;
Product Name: AC DC Hipot Tester;
Standard: IEC;
Power: Electric;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|