| Specification |
Type: Static Laser;
Sample Feeding: Dry and Wet;
Warranty: 2 Years;
Model: Nkt-N9;
Execution Standard: 29022-2012/ISO;
Measurement Range: 1-10000nm(Related with The Samples);
Concentration Range: 0.1mg/L-100mg/L;
Scattering Angle: 90;
Sample Chamber: 10mm*10mm, 4ml;
|
Type: Semiconductor Laser;
Sample Feeding: High-Pressure Syringe Pump Sampling;
Warranty: 1 Years;
Flow Rate: 5 -80ml/Min;
Range: 0.8μm-600μm;
Channels: 8-64 Channels Optional (Factory Default 64);
Principle: Photoresist (Shading) Counting Principle;
Sample Test Viscosity: ≤650cst;
Sampling Volume: 0.2~6000ml, Interval 0.1ml;
Sampling Accuracy: Better Than ±0.5%;
Sampling Speed: 5 ~80ml/Min;
Test Sample Temperature: 0℃-80℃;
Power Supply: 110~245V AC, 50/60Hz, 70W;
Host Size: 340mm×410mm×650mm;
Air Pump Size: 180mm×160mm×220mm;
Main Unit Net Weight: 23 Kg;
Air Pump Net Weight: 5.5kg;
|
Type: Semiconductor Laser;
Sample Feeding: High-Pressure Syringe Pump Sampling;
Warranty: 1 Years;
Principle: Photoresist (Shading) Counting Principle;
Flow Rate: 5 -80ml/Min;
Range: 0.8μm-600μm;
Channels: 64 Channels (Editable Channels), The Particle Size;
Sample Test Viscosity: ≤650cst;
Sampling Volume: 0.2~6000ml, Interval 0.1ml;
Sampling Accuracy: Better Than ±0.5%;
Sampling Speed: 5 ~80ml/Min;
Test Sample Temperature: 0℃-80℃;
Power Supply: 110~245V AC, 50/60Hz, 70W;
Host Size: 340mm×310mm×730mm;
Main Unit Net Weight: 22 Kg;
Air Pump Net Weight: 5.5kg;
|
Type: Semiconductor Laser;
Sample Feeding: High-Pressure Syringe Pump Sampling;
Warranty: 1 Years;
Principle: Photoresist (Shading) Counting Principle;
Flow Rate: 5 -80ml/Min;
Range: 0.8μm-600μm;
Channels: 64 Channels (Editable Channels), The Particle Size;
Sample Test Viscosity: ≤650cst;
Sampling Volume: 0.2~6000ml, Interval 0.1ml;
Sampling Accuracy: Better Than ±0.5%;
Sampling Speed: 5 ~80ml/Min;
Test Sample Temperature: 0℃-80℃;
Power Supply: 110~245V AC, 50/60Hz, 70W;
Host Size: 340mm×310mm×730mm;
Main Unit Net Weight: 22 Kg;
Air Pump Net Weight: 5.5kg;
|
Type: Semiconductor Laser;
Sample Feeding: High-Pressure Syringe Pump Sampling;
Warranty: 1 Years;
Principle: Photoresist (Shading) Counting Principle;
Flow Rate: 5 -80ml/Min;
Range: 0.8μm-600μm;
Channels: 64 Channels (Editable Channels), The Particle Size;
Sample Test Viscosity: ≤650cst;
Sampling Volume: 0.2~6000ml, Interval 0.1ml;
Sampling Accuracy: Better Than ±0.5%;
Sampling Speed: 5 ~80ml/Min;
Test Sample Temperature: 0℃-80℃;
Power Supply: 110~245V AC, 50/60Hz, 70W;
Host Size: 340mm×310mm×730mm;
Main Unit Net Weight: 22 Kg;
Air Pump Net Weight: 5.5kg;
|