| Specification |
Manufacturer: Honeywell;
Product Category: Board Mount Current Sensors;
Current Rating: 600 A;
Sensor Type: Open Loop;
Response Time: 3 us to 7 us;
Accuracy: 2 %;
Operating Supply Voltage: 15 Vdc;
Maximum Operating Temperature: + 80 °C;
Minimum Operating Temperature: -10 °C;
|
Type: Rogowski Coil Split Core Current Sensor;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Permalloy;
Accuracy Grade: 0.5G;
Application: Instruments;
IP Rating: IP30;
Customized: Customized;
Ratio: 1000: 1 or 2000:1, Customized;
Nominal Input: 1000A;
Max. Cont. Input Current: 1200 a;
Accuracy: 0.2%, 0.5%;
Output Signal: 500mA, 1A, 5A Acat Nominal Input Current;
Frequency Range: 40 Hz....2000 Hz;
Dielectric Strength: 3kv 50Hz/60Hz at 1 Minute;
Temperature Range: -20 °c...+55 °c;
Output: 2.5 Meter Cable with D01 Connector;
Types: Rogowski Coil Current Sensor;
|
Type: Current Transformer;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Permalloy;
Accuracy Grade: 0.5G;
Application: Instruments;
IP Rating: IP30;
Customized: Customized;
Ratio: 1000: 1 or 2000:1, Customized;
Nominal Input: 3000A;
Max. Cont. Input Current: 3600A;
Accuracy: 0.2%, 0.5%;
Output Signal: 500mA, 1A, 5A Acat Nominal Input Current;
Frequency Range: 40 Hz....2000 Hz;
Dielectric Strength: 3kv 50Hz/60Hz at 1 Minute;
Temperature Range: -20 °c...+55 °c;
Output: 2.5 Meter Cable with D01 Connector;
Types: Clamp on Current Transformers;
|
Type: Electromagnetic;
Production Process: Integration;
Material: Permalloy;
Customized: Customized;
Ratio: 1000: 1 or 2000:1, Customized;
Nominal Input: 3000A;
Max. Cont. Input Current: 3600 a;
Accuracy: 0.2%, 0.5%;
Output Signal: 500mA, 1A, 5A Acat Nominal Input Current;
Frequency Range: 40 Hz....2000 Hz;
Dielectric Strength: 3kv 50Hz/60Hz at 1 Minute;
Temperature Range: -20 °c...+55 °c;
Output: 2.5 Meter Cable with D01 Connector;
Max. Voltage Not Insulated Conductors: 600 V;
|
Type: Electromagnetic;
Output Signal Type: Analog Output;
Production Process: Injection+ABS;
Material: ABS or PC;
Accuracy Grade: 0.5G;
Application: Power, Electronic, Instrument;
IP Rating: IP65;
Customized: Customized;
Accuracy: 0.5s, 0.5% or 1%;
Ratio: 100/5A,200/5A, 400/5A, 800/5A, 1000/5A;
Second Current: 1A or 5A;
Standards: IEC 60044-1, IEC61869, Ntc 2205;
Fs: Less Than 5;
Weigt: 2.5kg;
Size: 350mm*283mm*55mm;
Aperture: 185mm;
Name: Outdoor Split Core Current Transformer;
Applications: Power Monitor Analyzer;
Diameter: 55mm Cable;
Using Installation: Outdoor;
|