| Specification |
Sample Feeding: Dry Dispersion;
Warranty: 1 Years;
Measurement Range: Capture Rate: Amount to 98%;
Sample Volume: 28.3L/Min;
Principle: Anderson Impact Principle;
Sampling Period: 1-99 Minutes Can Be Set Arbitrarily;
Noise: Amount to 50 dB;
Power Supply: 220V/AC;
Power: ≤ 45W;
Host Size: 210*250*130(mm) Weight:4.7kg;
Impactor Size: 110*110*850(mm) Weight:1.1kg;
|
Type: Static Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Meansure Range: 0.1-2000um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 0.1 Micron - 3000 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Weight: 38kgs;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
|
Type: Static Laser;
Sample Feeding: Droplet;
Warranty: 2 Years;
Meansure Range: 0.1-360um;
Optical Path Calibration: Automatic;
Channels Number: 54;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Nasal Drug Products/Aerosol Research;
Reference Particle Size: D90/D50/D10;
Measurement Range Option: 0.1micron - 360 Microns;
Repeatably Error: <1% (Average Particle Size of National Standard S;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 1 Minutes;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 13kgs;
Volume: 612mm*230mm*325mm;
|
Type: Static Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Meansure Range: 0.1-800um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion,;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 0.1 Micron - 600 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 38kgs;
|
Type: Portible, Dynamic Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Measurement Range: 1-10000nm;
Optical Path Calibration: Automatic;
Flusing Method: GB/T 29022-2012/ISO 22412:2008;
Application: Cement, Ceramics, Pharmaceuticals, Lotion;
Reference Particle Size: D10/D50/D90;
Concentration Range: 0.1mg/L-100mg/L;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: <1min/Times(Dispersion Time Without Sample);
Operation Temperature: 0-45 Degree;
Weight: 14kgs;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
|