| Specification |
Classification: Biological Diagnostics;
Type: Chemistry Analyzer;
Group: All;
Product Name: Auto Chemistry Analyzer;
Test Speed: 220t/H;
Analysis Method: End-Point, Fixed-Time, Rate, Turbidimetry;
Sample Positions: 49 Sample Positions, Including Calibration, Quali;
Reagent Positions: 56 Refrigerated Reagent Positions;
Sample Volume: 2UL ~70UL (0.1UL Stepping);
Reagent Volume: R1 & R2: 20UL ~350UL (1UL Stepping);
Sample & Reagent Probe: Liquid Level Sensor Function, Anti-Collision Func;
Probe Washing: Automatically Wash Interior and Exterior;
Reaction Time: 10 Minutes;
Cooling Function: 2ºC~8ºC Cooling for 24 Hours;
Temperature Control: 37ºC±0.1ºC, Real-Time Monitor;
Receiver: 8 Precision Photo Receivers;
Linear Range: 0.000~3.000ABS;
Computer System: Windows7/8/10, Lis System Available;
|
Classification: Biological Diagnostics;
Type: Elisa Processor;
Group: All;
Instrument Classification: Class II;
Power Supply: AC110/220V, 60/50Hz;
After-Sale Service: Online Technical Support;
Optical Path: 8 Channal Vertical Light Path System;
Software: Windows 7;
Temperature: 10~30degree;
Warranty: 1 Year;
Wavelength Range: 400-800nm;
Filter: Standard 4 Wavelengths of 405, 450, 492, 630nm;
Reading Range: 0.000~4.000 ABS;
|
Classification: Biological Diagnostics;
Type: Elisa Mircoplate Incubator;
Group: Middle-aged and Old;
Timing Range: 1min - 99h59min;
Display Accuracy: 0.1℃;
Shaking Speed: 200-1600rpm;
Capacity: 2PCS Microplates or Culture Plates;
Power Supply: 150W;
Orbit: 3mm;
Temp Uniformity: ±0.5℃;
Temp. Control Range: Rt.+5c-80℃;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Infusion Pump;
Group: All People;
Product Name: Infusion Pump;
Drug Library: up to 1030 Drugs Are Provided.;
Cumulative Infusion Volume: 0-9999.9ml;
Kvo Rate: 0.1 ~ 5.0ml/H;
Infusion Accuracy: 2%;
Power Supply: AC100-220V, 50/60Hz;
Features: Easy to Carry, Easy to Operate;
Infusion Set: Any Brand of Infusion Set;
Infusion Mode: Rate, Time, Dose, Drug Library and Sequential Mode;
Air Bubble Detection: Ultrasound Sensor Detection of Air Bubble;
|
Classification: Biochemical Apparatus;
Type: Biochemistry Analyzer;
Group: All;
Product Name: Auto Chemistry Analyzer;
Application: Hospital Clinic Laboratory;
Throughput: 400 Tests/Hour;
Reagent Positions: 90 Refrigerated Reagent Positions;
Sample Positions: 60 or 90 Sample Positions, Built-in Barcode System;
Probe: with Anti-Collision Function,Liqui;
Probe Washing: Automatic Washing Interior and Exterior;
Reagent Cooling: 2~8℃;
Temperature Control: 37±0.1℃, Real-Time Monitoring;
Cuvettes: 120reusable Cuvettes, Optical Length 6mm;
Water Consumption: Deionized Water:10L/H;
Net Weight: 190kg;
Package Size (W*D*H): 1348*928*1377mm;
Gross Weight: 257kg;