| Specification |
Type: Dynamic Laser;
Sample Feeding: Wet and Dry Process;
Warranty: 1 Year;
Product Name: Automatic Laser Particle Size Analyzer;
Wet Process Number of D Etector Channels: 112;
Dry Process Number of D Etector Channe: 102;
Test Aange: Wet Process: 0.01μm -1250μm;Dry Process: 0.1;
Test Speed: <1min/ Times (Excluding Sample Dispersion Time);
Accuracy Error: Dry Process: <1%,Wet Process: <1%;
Wet Process Classification: Ultrasonic, Cycle and Stir, Circulating Flow;
Dry Process Classification: Dispersion Mode, Feeding Method, Cold Dryer;
Package Size(mm): 1270*410*620;
Power: AC220V±10%, 50/60Hz(Standard) AC110±;
Cycle and Stir: Integrated Design of Circular Mixing, Speed: 100-3;
|
Type: Static Laser;
Sample Feeding: Wet Dispersion;
Warranty: 2 Years;
Meansure Range: 0.1-1000um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion,;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 0.1 Micron - 1000 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Standard;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Weight: 38kgs;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
|
Type: Static Laser;
Sample Feeding: Dry Dispersion;
Warranty: 2 Years;
Meansure Range: 0.1-2000um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement/Mineral Powder;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 0.01micron - 2000 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Channel Numbers: 76;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
Weight: 58kgs;
|
Type: Static Laser;
Sample Feeding: Wet&Dry;
Warranty: 2 Years;
Meansure Range: 0.1-2000um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 1 Micron - 2000 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Weight: 58kgs;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
|
Type: Static Laser;
Sample Feeding: Wet&Dry;
Warranty: 2 Years;
Meansure Range: 0.1-2000um;
Optical Path Calibration: Automatic;
Flusing Method: Automatic Instrument Flushing;
Executive Standard: GB/T 19077-2016/ISO 13320:2009;
Application: Cement, Ceramics, Pharmaceuticals, Lotion;
Reference Particle Size: D10/D50/D90;
Measurement Range Option: 1 Micron - 2000 Microns;
Repeatably Error: <0.5%(Average Particle Size of National Samples;
Software: Include with The Analyzer;
Testing Report: Automatically Generated After Testing;
Testing Speed: < 10 Seconds;
Operation Temperature: 0-45 Degree;
Weight: 58kgs;
Power Requirements: 220V (± 20V), 50Hz - 60Hz;
|