      Conventional Wire 2 Zone Fire Alarm Control Panel

      About this Item
      Details
      Company Profile

      Price

      Min. Order Reference FOB Price

      1 Piece US$100.00-105.00 / Piece

      Sepcifications

      • Type Fire Alarm Host
      • Function Non-Networked
      • Usage Fire
      • Certification CE
      • Wiring Mode Sub-Line System
      • Transport Package Carton
      • Specification 320X231X90
      • Trademark ASENWARE
      • Origin Guangdong, China
      • Mains Supply Voltage 110VAC or 220VAC
      • Internal Power Supply 27.2VDC
      • Number of Circuit 2
      • Output Type Nc and No Relay
      • Weight (with Batteries) 7kg

      Product Description

      Conventional wire 2 zone fire alarm control panel Introduction: The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull ...

      Learn More

      Wire 2 Zone Control Panel Comparison
      Transaction Info
      Price US$100.00-105.00 / Piece US$50.00-75.00 / Piece US$50.00-75.00 / Piece US$155.00-170.00 / Piece US$155.00-170.00 / Piece
      Min Order 1 Piece 1 Piece 1 Piece 1 Piece 1 Piece
      Payment Terms LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment LC, T/T, D/P, PayPal, Western Union, Small-amount payment
      Quality Control
      Product Certification CE CE CE CE CE
      Management System Certification - - - - -
      Trade Capacity
      Export Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe Europe, Southeast Asia/ Mideast, Domestic Europe, Southeast Asia/ Mideast, Domestic Europe, Southeast Asia/ Mideast, Domestic Europe, Southeast Asia/ Mideast, Domestic
      Annual Export Revenue - - - - -
      Business Model - - - - -
      Average Lead Time Peak Season Lead Time: within 15 workdays
      Off Season Lead Time: within 15 workdays
      Peak Season Lead Time: one month
      Off Season Lead Time: within 15 workdays
      Peak Season Lead Time: one month
      Off Season Lead Time: within 15 workdays
      Peak Season Lead Time: one month
      Off Season Lead Time: within 15 workdays
      Peak Season Lead Time: one month
      Off Season Lead Time: within 15 workdays
      Product Attributes
      Specification
      Type: Fire Alarm Host;
      Function: Non-Networked;
      Usage: Fire;
      Wiring Mode: Sub-Line System;
      Mains Supply Voltage: 110VAC or 220VAC;
      Internal Power Supply: 27.2VDC;
      Number of Circuit: 2;
      Output Type: Nc and No Relay;
      Weight (with Batteries): 7kg;
      Type: Fire Alarm Host;
      Function: Networked;
      Usage: Fire, Smoke;
      Alarm Volume (within 1m): ≥100dB;
      Networking Mode: Alarm;
      Receive Frequency: 485/232;
      Wiring Mode: Sub-Line System;
      Weight [Without Battery ]: 520g;
      Number of Zones: 4;
      Primary AC: 90-270VDC;
      Standby Battery: 2*12V;
      Detector Voltage(VDC): 24VDC;
      Maximum Number of Detectors Per Zone: 30;
      Type: Fire Alarm Host;
      Function: Networked;
      Usage: Fire, Smoke;
      Alarm Volume (within 1m): ≥100dB;
      Networking Mode: Alarm;
      Receive Frequency: 485/232;
      Wiring Mode: Sub-Line System;
      Weight: 7kg;
      Color: Red;
      Number of Zones: 4;
      Primary AC: 90-270VDC;
      Standby Battery: 2*12V;
      Type: Fire Alarm Host;
      Function: Networked;
      Usage: Auto, Fire, Smoke;
      Alarm Volume (within 1m): ≥100dB;
      Networking Mode: Dial-up;
      Receive Frequency: Wire;
      Wiring Mode: Sub-Line System;
      Primary AC: 90-270VAC 50/60 Hz;
      Number of System Zones: 4 Zone;
      Panel Weight: 4kg;
      Extinguishant Release Output: 2 AMP@28VDC;
      Alarm Zone End of Line (Ohms): 10K;
      Type: Fire Alarm Host;
      Function: Networked;
      Usage: Auto, Fire, Smoke;
      Alarm Volume (within 1m): ≥100dB;
      Networking Mode: Dial-up;
      Receive Frequency: Wire;
      Wiring Mode: Sub-Line System;
      Primary AC: 90-270VAC 50/60 Hz;
      Number of System Zones: 4 Zone;
      Panel Weight: 4kg;
      Extinguishant Release Output: 2 AMP@28VDC;
      Alarm Zone End of Line (Ohms): 10K;
      Supplier Name

      Shenzhen Asenware Test and Control Technology Co., Ltd.

      Diamond Member Audited Supplier

      Shenzhen Puzhesi Technology Co., Ltd.

      Diamond Member Audited Supplier

      Shenzhen Puzhesi Technology Co., Ltd.

      Diamond Member Audited Supplier

      Shenzhen Puzhesi Technology Co., Ltd.

      Diamond Member Audited Supplier

      Shenzhen Puzhesi Technology Co., Ltd.

      Diamond Member Audited Supplier