| Specification |
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: TCP/IP;
Wiring Mode: Bus System;
Mains Supply: 230VAC;
Operating Voltage: 18.5 ~ 30VDC;
Max. Output Current: 0.5A;
Approx. Weight (Without Battery): 14kg;
Address: 324points/1 Loop;
Max. Charging Current: 1.2A;
Max. Battery Supply Current: 4A;
Size: 430× 560× 170mm;
Quiescent Current (Full Loaded): < 0.4A;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: CAN;
Wiring Mode: Bus System;
Product Name: Addressable Fire Alarm Control Panel;
Main Power Supply: AC 220V±20%/50Hz or DC24V;
Backup Power Supply: DC24V Battery Bat12V/5ah;
Ambient Temperature: -10 to +55 Celsius Degree;
Ambient Humidity: ≤95% No Condensation;
Loop Capacity: 100 / 200 / 324 / 648 Points;
Loop Extension: up to 16 Loops (AS-9108E);
Display: 4.3" LCD Display;
Mini-Printer: Optional;
USB Interfaces: Yes;
LED Indicators: Yes;
Control Buttons: Yes;
Network: Can Bus Networkable;
Standard: EN54-2 & EN54-4;
Application: Office, Factory, Warehouse, Apartment, Hotel etc.;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: CAN;
Wiring Mode: Bus System;
Product Name: Addressable Fire Alarm Control Panel;
Main Power Supply: AC 220V±20%/50Hz or DC24V;
Backup Power Supply: DC24V Battery Bat12V/5ah;
Ambient Temperature: -10 to +55 Celsius Degree;
Ambient Humidity: ≤95% No Condensation;
Loop Capacity: 100 / 200 / 324 / 648 Points;
Loop Extension: up to 16 Loops (AS-9108E);
Display: 4.3" LCD Display;
Mini-Printer: Optional;
USB Interfaces: Yes;
LED Indicators: Yes;
Control Buttons: Yes;
Network: Can Bus Networkable;
Standard: EN54-2 & EN54-4;
Application: Office, Factory, Warehouse, Apartment, Hotel etc.;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Conventional Fire Alarm Contorl Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|